A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dynamics of ventilation, heart rate, and gas exchange: sinusoidal and impulse work loads in man. | LitMetric

Dynamic characteristics of ventilation, heart rate, and gas exchange in response to sinusoidally varying work loads were analyzed in four male subjects, exercising in the upright position on a bicycle ergometer. Mean work-load and sinusoidal amplitude were about 1.5 and 0.9 W/kg, fat-free mass), respectively. Seven different frequencies were used, the periods ranging from 12 to 0.75 min. To further investigate the linearity of the variables under study, 10-s impulse loads were also applied to three of the four subjects. Harmonic analysis of the sine-wave data and comparison of the sine-wave fundamental responses with the impulse frequency responses showed that only O2 uptake behaves in a linear fashion. Ventilation and CO2 production showed quasi- to nonlinear behaviors, whereas the responses of heart rate and alveolar partial pressures were clearly dependent on the type of forcing used. By means of mathematical parameter identification techniques, it was found that the individual frequency responses of O2 uptake could be almost completely described by a four-parameter transfer function with parameter values showing second-order underdamped to critically damped dynamics.

Download full-text PDF

Source
http://dx.doi.org/10.1152/jappl.1980.48.2.289DOI Listing

Publication Analysis

Top Keywords

heart rate
12
ventilation heart
8
rate gas
8
gas exchange
8
work loads
8
frequency responses
8
responses uptake
8
dynamics ventilation
4
exchange sinusoidal
4
sinusoidal impulse
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!