The repetitive nature of cardiac waveforms renders them suitable for processing by signal averaging. A flexible system is described, based on a general-purpose digital computer, capable of averaging a variety of cardiac signals in excess of 0.5 microV containing frequency components below a theoretical Nyquist limit of 5 kHz. Important features of the system include real-time processing capability at a high level of interactive control, and the facility to trigger the averaging process accurately from any part of either the data or a synchronous reference waveform. Application of the system to electrocardiographic and phonocardiographic signals at conventional gain has enabled clinically useful records to be obtained in the face of obtrusive environmental noise. The averaging of signals of a similar nature after considerably increased amplification has revealed cardiac activity unseen in conventional records in a total of 81 subjects.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0141-5425(80)90087-4DOI Listing

Publication Analysis

Top Keywords

cardiac waveforms
8
flexible signal-averaging
4
system
4
signal-averaging system
4
cardiac
4
system cardiac
4
waveforms repetitive
4
repetitive nature
4
nature cardiac
4
waveforms renders
4

Similar Publications

Significance: Cerebral blood flow (CBF) and cerebral blood volume (CBV) are key metrics for regional cerebrovascular monitoring. Simultaneous, non-invasive measurement of CBF and CBV at different brain locations would advance cerebrovascular monitoring and pave the way for brain injury detection as current brain injury diagnostic methods are often constrained by high costs, limited sensitivity, and reliance on subjective symptom reporting.

Aim: We aim to develop a multi-channel non-invasive optical system for measuring CBF and CBV at different regions of the brain simultaneously with a cost-effective, reliable, and scalable system capable of detecting potential differences in CBF and CBV across different regions of the brain.

View Article and Find Full Text PDF

Peptide ion mobility adds an extra dimension of separation to mass spectrometry-based proteomics. The ability to accurately predict peptide ion mobility would be useful to expedite assay development and to discriminate true answers in a database search. There are methods to accurately predict peptide ion mobility through drift tube devices, but methods to predict mobility through high-field asymmetric waveform ion mobility (FAIMS) are underexplored.

View Article and Find Full Text PDF

The local pulse wave velocity (PWV) from large elastic arteries and its pressure-dependent changes within a cardiac cycle are potential biomarkers for cardiovascular risk stratification. However, pulse wave reflections can impair the accuracy of local PWV measurements. We propose a method to measure pressure-dependent variations in local PWV while minimizing the influence of pulse wave reflections.

View Article and Find Full Text PDF

Introduction: Effective defibrillation is essential to out-of-hospital cardiac arrest (OHCA) survival. International guidelines recommend initial defibrillation energies between 120 and 360 Joules, which has led to widespread practice variation. Leveraging this natural experiment, we aimed to explore the association between initial defibrillation dose and outcome following OHCA.

View Article and Find Full Text PDF

Ultrasonography (US) is a sensitive and radiation-free technique for diagnosing deep vein thrombosis (DVT). Therefore, when DVT is clinically suspected but not detected on US, radiologists should consider a range of alternative differential diagnoses. This review article presents the imaging findings of clinical conditions that mimic DVT, which can be distinguished using a multimodal radiologic approach.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!