Swanson's silastic implants in great toes.

J Bone Joint Surg Br

Published: February 1980

This is a review of 77 partial replacement and interposition arthroplasties in which Silastic implants were used. The operations were carried out between 1971 and 1977 on the metatarsophalangeal joints of the great toes of 62 patients. Twenty-six of the operations were for painful hallux rigidus and 51 for hallux valgus. The patients were reviewed 12 to 92 months after operation, the average follow-up being 60 months. The analysis of results indicated that while the procedure may be suitable for hallux rigidus its use for hallux valgus is not fully satisfactory in the long run.

Download full-text PDF

Source
http://dx.doi.org/10.1302/0301-620X.62B1.7351441DOI Listing

Publication Analysis

Top Keywords

silastic implants
8
great toes
8
hallux rigidus
8
rigidus hallux
8
hallux valgus
8
swanson's silastic
4
implants great
4
toes review
4
review partial
4
partial replacement
4

Similar Publications

Silicon integrated circuits (ICs) are central to the next-generation miniature active neural implants, whether packaged in soft polymers for flexible bioelectronics or implanted as bare die for neural probes. These emerging applications bring the IC closer to the corrosive body environment, raising reliability concerns, particularly for chronic use. Here, we evaluate the inherent hermeticity of bare die ICs, and examine the potential of polydimethylsiloxane (PDMS), a moisture-permeable elastomer, as a standalone encapsulation material.

View Article and Find Full Text PDF

A positionally stable anatomic smooth breast implant.

Biomed Mater

December 2024

Laboratory of Bioregenerative Medicine & Surgery, Department of Surgery, Division of Plastic Surgery, Weill Cornell Medical College, New York, NY, United States of America.

The voluntary recall of textured breast implants due to their association with breast implant-associated anaplastic large cell lymphoma has resulted in the loss of the primary advantage of the textured surface: positional stability. We have engineered a novel soft gel-filled smooth implant with a surface that promotes positional stability without texture, known as the positionally stable smooth implant (PSSI). Miniature anatomically shaped breast implant shells were fabricated from polydimethylsiloxane using 3D-printed molds.

View Article and Find Full Text PDF

Objective: Type 1 Thyroplasty is a well-established procedure used for medializing an immobile vocal fold. Silastic and Gore-Tex are the two most common materials used to accomplish this, but comparative data on their relative efficacy are scarce. We sought to compare outcomes between Silastic and Gore-Tex implants via systematic review and meta-analysis for unilateral vocal fold immobility.

View Article and Find Full Text PDF

Impact of microchannel width on axons for brain-on-chip applications.

Lab Chip

November 2024

Laboratory of Biosensors and Bioelectronics (LBB), ETH Zürich, 8092 Zürich, Switzerland.

Technologies for axon guidance for disease models and bottom up investigations are increasingly being used in neuroscience research. One of the most prevalent patterning methods is using polydimethylsiloxane (PDMS) microstructures due to compatibility with microscopy and electrophysiology which enables systematic tracking of axon development with precision and efficiency. Previous investigations of these guidance platforms have noted axons tend to follow edges and avoid sharp turns; however, the specific impact of spatial constraints remains only partially explored.

View Article and Find Full Text PDF

Low-dose estrogen release from silastic capsule enhanced flap wound healing in an animal model.

Int Wound J

October 2024

Burn Center and Division of Plastic and Reconstructive Surgery, Department of Surgery, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan.

Article Synopsis
  • Flap transplantation is often used for extensive wounds, relying on stable blood flow, and previous studies showed that high doses of estrogen improve flap survival but may cause side effects due to unnatural concentrations.
  • This study tested the effects of sustained-release estrogen capsules at lower, physiological levels on flap survival in ovariectomized mice, focusing on blood perfusion and wound healing indicators.
  • Results indicated that lower doses of estrogen improved blood flow and reduced necrosis while impacting specific markers related to tissue oxygen levels and cell death, suggesting that physiological estrogen levels can still be beneficial for flap survival.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!