Linear contrast echo configuration on the pulmonary valve M-mode echogram was assessed in 28 patients with pulmonary hypertension, in 10 with pulmonary regurgitation, and in 10 normal subjects. Contrast echo parallel lines filling the total systolic phase of the pulmonary valve were recorded in normal subjects. Contrast echo lines stopping in early systole around the pulmonary valve mid-systolic notch were seen in all the patients with pulmonary hypertension in relation to changes with the pulmonary flow. Contrast echo lines reversing the early diastole and crossing the pulmonary valve echogram during diastole were detected in all the patients with pulmonary regurgitation, consistent with the reversed flow across the valve. The use of contrast echocardiography to diagnose both pulmonary hypertension and regurgitation may provide further useful information, particularly when the orientation and time of appearance of the contrast echo lines are related to the systolic and/or diastolic phases of the pulmonary valve M-mode echogram.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC482662 | PMC |
http://dx.doi.org/10.1136/hrt.46.4.369 | DOI Listing |
Med J Malaysia
January 2025
Universiti Sains Malaysia, School of Medical Sciences, Department of Radiology, Health Campus, Kubang Kerian, Kelantan, Malaysia.
Introduction: Contrast-enhanced ultrasound (CEUS), an in vivo imaging tool for evaluating intraplaque neovascularisation (IPN), is an increasingly researched marker of susceptible atherosclerotic plaque. This study aims to assess the feasibility of quantifying carotid IPN using CEUS and to identify and characterise the neovascularisation in carotid plaques. The hospital's ethical committee approved the study, and the informed individual consent form of CEUS was obtained from all patients before the examination.
View Article and Find Full Text PDFEur Heart J Imaging Methods Pract
January 2025
A.I. Virtanen Institute, University of Eastern Finland, Neulaniementie 2, 70210 Kuopio, Finland.
Aims: The aim of this study was to develop an ultra-short echo time 3D magnetic resonance imaging (MRI) method for imaging subacute myocardial infarction (MI) quantitatively and in an accelerated way. Here, we present novel 3D T- and T -weighted Multi-Band SWeep Imaging with Fourier Transform and Compressed Sensing (MB-SWIFT-CS) imaging of subacute MI in mice hearts .
Methods And Results: Relaxation time-weighted and under-sampled 3D MB-SWIFT-CS MRI were tested with manganese chloride (MnCl) phantom and mice MI model.
AJNR Am J Neuroradiol
January 2025
From the Department of Radiology, Medical University of South Carolina, Charleston, SC, USA (MVS, HRC, WD, JHC, JAC, MGM, STS, DRR), College of Medicine, Medical University of South Carolina, Charleston, SC, USA (HW, EY).
Background And Purpose: Magnetic Resonance Imaging is widely used to assess disease burden in multiple sclerosis (MS). This study aimed to evaluate the effectiveness of a commercially available k-nearest neighbors (k-NN) software in quantifying white matter lesion (WML) burden in MS. We compared the software's WML quantification to expert radiologists' assessments.
View Article and Find Full Text PDFRheumatol Int
January 2025
Department of Diagnostic and Interventional Radiology, University Hospital Wuerzburg, Oberduerrbacher Strasse 6, 97080, Wuerzburg, Germany.
Background: Diagnosis of Giant Cell Arteritis (GCA) and Polymyalgia rheumatica (PMR) may be challenging as many patients present with non-specific symptoms. Superficial cranial arteries are predilection sites of inflammatory affection. Ultrasound is typically the diagnostic tool of first choice supplementary to clinical and laboratory examination.
View Article and Find Full Text PDFJ Med Ultrasound
February 2024
Department of Electrical Engineering, Computer Engineering and Informatics, Cyprus University of Technology, Limassol, Cyprus.
Background: The main goal of the study was to find the magnetic resonance imaging (MRI) parameters that optimize contrast between tissue and thermal lesions produced by focused ultrasound (FUS) using T1-weighted (T1-W) and T2-weighted (T2-W) fast spin echo (FSE) sequences.
Methods: FUS sonications were performed in porcine tissue using a single-element FUS transducer of 2.6 MHz in 1.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!