One hundred and eight patients were studied with fluid-filled oculoplethysmography and carotid phonoangiography (OPG-CPA) and by arteriography. Thirty-two patients also had "Doppler evaluation" of supraorbital arterial flow. The OPG-CPA correctly predicted the degree of occlusion in 76% of the involved vessels, including the degree of occlusion of each carotid for each patient (63%). The OPG-CPA identified at least one obstructing carotid lesion in 51 of the 56 (91%) patients with obstructing lesions demonstrated by arteriography. On a per patient basis, which requires that both carotids be correctly assessed, the OPG-CPA had a false negative rate of 9.6% and false positive rate of 50%. The supraorbital artery "Doppler evaluation" had an accuracy rate of 66%, a per patient false negative rate of 50%, and a per patient false positive rate of 12%. The OPG-CPA and supraorbital artery "Doppler evaluation" are adjunctive tests for evaluating patients with cerebral vascular insufficiency and should not, at present, replace arteriography in symptomatic patients or in certain asymptomatic patients.

Download full-text PDF

Source
http://dx.doi.org/10.1161/01.str.12.3.317DOI Listing

Publication Analysis

Top Keywords

"doppler evaluation"
12
oculoplethysmography carotid
8
carotid phonoangiography
8
degree occlusion
8
false negative
8
negative rate
8
false positive
8
positive rate
8
rate 50%
8
supraorbital artery
8

Similar Publications

The introduction of devices for endovascular dialysis access creation (WavelinQ and Ellipsys) offers practitioners more options for access management in dialysis patients. Especially in terms of reducing the usage of central venous catheters, a native fistula is desirable as an initial dialysis access. We present a case in which a failed WavelinQ type fistula was reactivated using the Ellipsys procedure on the same arm.

View Article and Find Full Text PDF

Ethnopharmacology Relevance: Incorporating ancient wisdom from Unani Medicine, this study delves into the therapeutic efficacy of Juniperus communis L. in primary dysmenorrhea. By seamlessly merging traditional knowledge with modern scientific evaluation, this research illuminates Juniperus communis L.

View Article and Find Full Text PDF

Background: Pulmonary embolism (PE) is one of the most challenging diagnoses in emergency medicine, mainly because symptoms range from asymptomatic disease to sudden death. The role of echocardiography in the workup of suspected PE has been supportive and used primarily to assess the right ventricular (RV) size and function, which is important for risk stratification. Several echocardiographic parameters described in the literature lack the desired accuracy.

View Article and Find Full Text PDF

Introduction: The objective of this study was to assess the relationship between longitudinal changes in the uterine Doppler velocimetry and the maternal profile of angiogenic factors in the third trimester and to assess their ability to predict term preeclampsia (PE).

Methods: A cohort of low-risk pregnant women was scheduled for a uterine Doppler evaluation and measurement of the circulating levels of angiogenic factors at ∼30 and ∼36 weeks. The performance of both parameters and their change over time in predicting term PE was evaluated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!