In 24 children with atrial septal defect of the secundum type and/or partial anomalous pulmonary venous connection, the pulmonary to systemic blood flow ratio (Qp/Qs) was estimated by echocardiography. Using M-mode echocardiography, right ventricular diameter (RVD), left ventricular diameter (LVD), total cardiac diameter (TCD) and aortic root (AOR) were measured, and the following 5 indices were obtained: RVD/LVD, RVD/TCD, RVD/AOR, RVD/BSA (body surface area) and TCD/BSA. The single linear correlation coefficients between these 5 indices and Qp/Qs, obtained by the Fick method during cardiac catheterization, were 0.88, 0.80, 0.74, 0.75 and 0.55, respectively. Thus, RVD/LVD ratio was the most sensitive echocardiographic index to assess Qp/Qs in these children. Clinically, however, the multiple linear regression equation derived from 3 indices (RVD/BSA, RVD/LVD and TCD/BSA) might be more useful (r = 0.89). Although the abnormal motion of the interventricular septum was analyzed, the quantification of this motion as an index of Qp/Qs was difficult.

Download full-text PDF

Source
http://dx.doi.org/10.1253/jcj.45.639DOI Listing

Publication Analysis

Top Keywords

qp/qs children
8
children atrial
8
atrial septal
8
septal defect
8
partial anomalous
8
anomalous pulmonary
8
pulmonary venous
8
venous connection
8
ventricular diameter
8
qp/qs
5

Similar Publications

4D flow cardiac magnetic resonance in pediatric congenital heart disease: Insights from over four years of clinical practice.

Clin Imaging

January 2025

Institute of Clinical sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Dept of Pediatric Radiology, The Queen Silvia Children's Hospital, Region Västra Götaland, Sahlgrenska University Hospital, Gothenburg, Sweden.

Background: Congenital heart diseases (CHDs) are common birth defects. This work presents over four years of clinical experience of 4D flow cardiovascular magnetic resonance (CMR), highlighting its value for pediatric CHD.

Methods: Children with various CHD diagnoses (n = 298) were examined on a 1.

View Article and Find Full Text PDF
Article Synopsis
  • - The study investigated the relationship between oxidative stress, measured by reactive oxygen metabolites (d-ROMs), and pulmonary hemodynamics in children with left-to-right shunt congenital heart disease (CHD) by comparing 60 CHD patients to 60 healthy controls.
  • - Findings revealed that d-ROM levels were significantly higher in the CHD group, and there were strong positive correlations between d-ROMs and key hemodynamic parameters, such as the pulmonary-to-systemic blood flow ratio and mean pulmonary arterial pressure.
  • - The diagnostic performance of d-ROMs for predicting a Qp/Qs ratio greater than 1.5 showed promise, with an area under the curve of 0.806, suggesting d-ROMs could
View Article and Find Full Text PDF

Objectives: The percentage of shunt fraction significantly impacts the management of patients with congenital shunts, influencing strategic choices such as surgical or interventional procedures. This study compared the estimated shunt fraction (the ratio of pulmonary-to-systemic flow, Qp/Qs) for quantifying the left-to-right shunt in children with ventricular septal defect (VSD) using heart catheterization, four-dimensional (4D) flow, and two-dimensional (2D) flow magnetic resonance imaging (MRI). The goal was to establish a non-invasive and reliable measurement ratio between pulmonary and systemic blood flow in these patients.

View Article and Find Full Text PDF

Background: This study aimed to validate respiratory-resolved five-dimensional (5D) flow cardiovascular magnetic resonance (CMR) against real-time two-dimensional (2D) phase-contrast MRI, assess the impact of number of respiratory states, and measure the impact of respiration on hemodynamics in congenital heart disease (CHD) patients.

Methods: Respiratory-resolved 5D flow MRI-derived net and peak flow measurements were compared to real-time 2D phase-contrast MRI-derived measurements in 10 healthy volunteers. Pulmonary-to-systemic flow ratios (Qp:Qs) were measured in 19 CHD patients and aortopulmonary collateral burden was measured in 5 Fontan patients.

View Article and Find Full Text PDF

Background: Pulse pressure variation (PPV) is based on heart-lung interaction and its association with the imbalance between pulmonary and systemic blood flow (Qp:Qs) has been understudied. We hypothesized that (1) baseline PPV (after induction of anesthesia) is different in a mixed congenital heart disease population with different Qp:Qs, (2) baseline PPV is different between a pooled group with high Qp:Qs and one with low Qp:Qs, and (3) a systemic-pulmonary shunt procedure results in reduced PPV compared to baseline.

Methods: We retrospectively reviewed the medical charts of children who presented to the operating room for cardiac surgery between 2010 and 2018.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!