Computed tomography (CT) scans of skeletal muscles of 3 patients with pseudohypertrophic muscular dystrophy are presented. Different patterns of muscle alterations and particularly of pseudohypertrophy are described. The significance of the radiological findings for clinical examination, electromyography, and needle biopsy is discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mus.880040112DOI Listing

Publication Analysis

Top Keywords

computed tomography
8
tomography muscle
4
muscle computed
4
tomography scans
4
scans skeletal
4
skeletal muscles
4
muscles patients
4
patients pseudohypertrophic
4
pseudohypertrophic muscular
4
muscular dystrophy
4

Similar Publications

Epilepsy Stands Nearby: A Pilot CT Perfusion Study on Post-Stroke Non-Convulsive Status Epilepticus.

Eur J Neurol

February 2025

IRCCS Istituto delle Scienze Neurologiche di Bologna, Department of Neurology and Stroke Center, Maggiore Hospital, Bologna, Italy.

Background: To investigate the relevance of hyperperfusion on computerised perfusion imaging (CTP) in the emergency setting in people with non-convulsive status epilepticus (NCSE) and previous stroke, to derive relevant aspects on the epileptogenic focus and the network recruited for NCSE propagation.

Methods: We enrolled consecutive adult patients with acute-onset NCSE and a previous stroke at a single institution undergoing CTP and EEG during symptoms. All patients underwent standard imaging including CT, CTP, CT angiograms and standard EEG within 30 min from hospital arrival.

View Article and Find Full Text PDF

Background: The use of iodinated contrast-enhancing agents in computed tomography (CT) improves the visualization of relevant structures for radiotherapy treatment planning (RTP). However, it can lead to dose calculation errors by incorrectly converting a CT number to electron density.

Purpose: This study aimed to propose an algorithm for deriving virtual non-contrast (VNC) electron density from dual-energy CT (DECT) data.

View Article and Find Full Text PDF

Purpose: To compare same-day photon-counting detector CT (PCD-CT) to conventional energy-integrating detector CT (EID-CT) for detection of small renal stones (≤ 3 mm).

Methods: Patients undergoing clinical dual-energy EID-CT for known or suspected stone disease underwent same-day research PCD-CT. Patients with greater than 10 stones and no visible stones under 3 mm were excluded.

View Article and Find Full Text PDF

Medical image annotation is scarce and costly. Few-shot segmentation has been widely used in medical image from only a few annotated examples. However, its research on lesion segmentation for lung diseases is still limited, especially for pulmonary aspergillosis.

View Article and Find Full Text PDF

Influence of two different printing methods on the accuracy of full-guided implant insertion - a laboratory study in undergraduate dental students.

BDJ Open

January 2025

Department of Oral and Maxillofacial Surgery (Head: Prof. Dr. Dr. Bernd Lethaus), University Hospital Tübingen, Eberhard Karls Universität Tübingen, Osianderstr. 2-8, D-72076, Tübingen, Germany.

Objectives: The aim of the present study was to compare the accuracy of fully guided implant insertion in vitro achieved by two fabrication methods in a cohort of undergraduates. We hypothesized that both methods achieve a comparable accuracy.

Methods: Surface scans and cone beam computed tomography images of 48 mandibular models were matched.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!