Atrioventricular conduction characteristics were examined by atrial extrastimulus technique in 45 children aged 50 days to 14 years following diagnostic cardiac catheterization. None of the patients had a history of supraventricular tachycardia and none had evidence of pre-excitation on routine electrocardiogram. By plotting the A2H2 and H1H2 intervals against corresponding S1S2 intervals 2 types of conduction curve were obtained. Eight of the 45 children (17.7%) showed discontinuous conduction curves, characteristic of dual atrioventricular nodal pathways, whereas 37 patients had continuous curves. Of the 8 patients with discontinuous curves 3 showed unsustained echo beats following extrastimuli, after the effective refractory period of the fast pathway was reached. This study showed that, as in adults, the atrioventricular node was frequently functionally dissociated in children.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1536/ihj.22.103 | DOI Listing |
J Cardiovasc Dev Dis
December 2024
Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary.
Background: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators.
Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed.
Pan Afr Med J
December 2024
Department of Cardiology, Aristide Le Dantec Hospital, Dakar, Senegal.
Introduction: cardiac pacing is the only lifesaving procedure which is effective for major cardiac conduction disorders. In sub-Saharan Africa, few pacemakers are implanted, compared to Western countries. This study aimed to describe the indications for cardiac pacing in four hospitals in Senegal, to evaluate its practical modalities, to identify pacemaker's complications and their predisposing factors and to evaluate the main challenges for cardiac pacing in Senegal.
View Article and Find Full Text PDFAnn Noninvasive Electrocardiol
January 2025
Cardiovascular Institute-Hospital Clínico San Carlos, Madrid, Spain.
We present the case of an 80-year-old female with acute pulmonary edema and a dual chamber pacemaker with intermittent short AV delays in the surface ECG after blocked premature atrial contractions (PACs). The behavior was consistent with the programmed Window of Atrial Rate Acceleration Detection (WARAD) and did not require further parameter modifications. As most cardiologists and emergency department physicians are not familiar with brand-specific algorithms, we believe that this case report will make these noncompetitive atrial pacing algorithms more accessible to non-cardiologists.
View Article and Find Full Text PDFCardiol Res
December 2024
Department of Cardiology, Fukuoka University Hospital, Fukuoka, Japan.
An 83-year-old man underwent dual-chamber pacemaker placement for complete atrioventricular block at another hospital. The active-fixation ventricular lead was positioned on the free wall of the anterior right ventricle. Ventricular pacing failure occurred on the day after pacemaker implantation, and fluoroscopy revealed right ventricular (RV) lead perforation.
View Article and Find Full Text PDFFront Physiol
December 2024
Department of Cardiology, First Affiliated Hospital of Dalian Medical University, Dalian, China.