Two sustained release formulations of 40 mg isosorbide dinitrate, encapsulated pellets and a tablet, were compared double blind following oral administration of single doses in terms of response on finger pulse plethysmography in nine healthy male volunteers. Following both formulations there was a distinct effect on the depth of b-wave in the first derivative of the finger pulse up to 9 h after administration. This change of the parameter of nitrate action was significantly different from placebo for both formulations. The onset of action was more rapid and the peak response greater for the capsule than for the tablet. The overall effects in terms of area under the effect-time curves was also greater for the capsule than for the tablet, however, not statistically significant. Furthermore, the results show that the method of finger pulse plethysmography can be used to determine onset and duration of action nitrate compounds, after single dose administrations.
Download full-text PDF |
Source |
---|
Intensive Care Med Exp
January 2025
Department of Emergency Medicine in Linköping, and Department of Biomedical and Clinical Sciences, Linköping University, 582 25, Linköping, Sweden.
Background: This study aimed to investigate whether changes in capillary refill (CR) time precede macrovascular signs of deterioration in a human model of blood loss shock. The study was conducted at the Department of Emergency Medicine in Linköping, Sweden, and involved 42 healthy volunteers aged 18-45. Participants were randomized into two provocations of applied lower body negative pressure (LBNP): a stepwise escalation protocol and a direct application protocol, to simulate gradual and acute blood loss.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Life Sciences, The University of Tokyo, Tokyo, Japan.
Many theories of time perception propose the existence of an internal pacemaker, and studies across behavioral, physiological, and neuroscience fields have explored this concept. Specifically, Spontaneous Motor Tempo (SMT), the most comfortable and natural tapping tempo for each individual, is thought to reflect this internal pacemaker's tempo. Changes in heart rate are also linked to time estimation, while Individual Alpha Frequency (IAF), the peak in the alpha range (8-13 Hz) observed in EEG, is reported to reflect the brain's temporal processing.
View Article and Find Full Text PDFEur J Prev Cardiol
January 2025
Amsterdam UMC, University of Amsterdam, Department Vascular Medicine, Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands.
Aims: Cross-correlation baroreflex sensitivity (xBRS) and heart rate variability (HRV) are measures of autonomic cardiac control and are associated with hypertension. However, their value in predicting new-onset hypertension and changes in systolic blood pressure (SBP) remains elusive.
Methods: We used longitudinal data of participants with- and without a history of cardiovascular disease from the HEalthy Life In an Urban Setting (HELIUS) study.
J Appl Physiol (1985)
January 2025
School of Kinesiology, Western University, London, Ontario, Canada.
The compliant nature of cerebral blood vessels may represent an important mechanical protection for sustained cerebral perfusion during reductions in arterial blood pressure (ABP). However, whether the rise in cerebrovascular compliance (Ci) with falling ABP persists and exhibits a threshold effect remains unknown. Therefore, we analyzed Ci changes during graded head-up tilt (HUT) in individuals with autonomic failure (AF), a group that tolerates graded and progressive reductions in ABP.
View Article and Find Full Text PDFNanomaterials (Basel)
December 2024
Quantum Nano Centre, Department of Chemical Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
Laser conversion of commercial polymers to laser-induced graphene (LIG) using inexpensive and accessible CO lasers has enabled the rapid prototyping of promising electronic and electrochemical devices. Frequently used to pattern interdigitated supercapacitors, few approaches have been developed to pattern batteries-in particular, full cells. Herein, we report an LIG-based approach to a planar, interdigitated Li-S battery.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!