Laboratory experiments were conducted to simulate radiopollutant effluents released to the atmosphere from two standard-design nuclear power plants. The main objective of the study was to compare the dispersion in the wakes of the plants with that in a simulated atmospheric boundary layer. Dispersion functions are determined that describe the spread of the effluent plume in the wake of each plant. These dispersion functions are described by power laws. They are determined for three incident wind angles and the number of stacks associated with each plant. Lateral plume spread was directly related to the silhouette area of the plants. A graphical technique is presented relating the lateral dispersion to the associated silhouette area of the building or building complex.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00004032-198212000-00005DOI Listing