In hypothalamic diabetes insipidus, water balance is achieved primarily through the thirst mechanism. The administration of an antidiuretic agent in the drinking water should restore the antidiuretic response to volume and osmoregulatory drive. To test this hypothesis, homozygous Brattleboro strain rats were given arginine vasopressin (AVP) or 1-desamino-8-D-arginine vasopressin (dDAVP) in the drinking water in concentrations of 10-10,000 micrograms/l (AVP) and 5-10,000 micrograms/l (dDAVP). Oral AVP was found to be ineffective. Oral dDAVP resulted in 1) a progressive increase in dDAVP dose, from 2.3 to 2,559 micrograms.day-1.kg-1; 2) a dose-dependent increase in urine osmolality from 306 to 1,796 mosmol/kg; and 3) a dose-dependent decrease in urinary solute excretion. At each dDAVP dose level, stable physiological states were achieved within 24 h. Similar antidiuretic states were achieved when dDAVP was administered in increasing doses or when therapy was initiated at a high dose. These findings demonstrate that inclusion of an appropriate antidiuretic agent in the drinking water can restore the renal response to volume-osmoregulatory drive.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1152/ajpregu.1982.243.5.R491 | DOI Listing |
Sci Total Environ
January 2025
Graduate School of Frontier Sciences, The University of Tokyo, Kashiwa 277-8563, Chiba, Japan; Atmosphere and Ocean Research Institute, The University of Tokyo, Kashiwa 277-8564, Chiba, Japan.
In recent decades, microplastics (MPs) have emerged as one of the biggest environmental challenges in aquatic environments. Ingestion and toxicity of MPs in seawater (SW) and freshwater (FW) fish have been studied extensively both in field and laboratory settings. However, the basic mechanism of how fish deal with MPs in SW and FW remains unclear, although physiological conditions of fish differ significantly in the two environments.
View Article and Find Full Text PDFSci Total Environ
January 2025
China National Environmental Monitoring Centre, Beijing 100012, China.
The riverine dissolved organic matter (DOM) pool constitutes the largest and most dynamic organic carbon reservoir within inland aquatic systems. Human activities significantly alter the distribution of organic matter (OM) in rivers, thereby affecting the availability of DOM. However, the impact of total suspended solids (TSS) on DOM under anthropogenic influence remains insufficiently elucidated.
View Article and Find Full Text PDFSci Total Environ
January 2025
Institute of Agrochemistry and Food Technology, IATA-CSIC, Av. Agustín Escardino 7, Paterna, Valencia 46980, Spain. Electronic address:
Human enteric viruses and emerging viruses such as severe acute respiratory syndrome coronavirus 2, influenza virus and monkeypox virus, are frequently detected in wastewater. Human enteric viruses are highly persistent in water, but there is limited information available for non-enteric viruses. The present study evaluated the stability of hepatitis A virus (HAV), murine norovirus (MNV), influenza A virus H3N2 (IAV H3N2), human coronavirus (HCoV) 229E, and vaccinia virus (VACV) in reference water (RW), effluent wastewater (EW) and drinking water (DW) under refrigeration and room temperature conditions.
View Article and Find Full Text PDFWater Res
January 2025
State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin, 150090, PR China. Electronic address:
Residual aluminum (Al) is a growing pollutant in nanofiltration (NF) membrane-based drinking water treatment. To investigate the impact of distinct Al species fouling layers on gypsum scaling during NF, gypsum scaling tests were conducted on bare and three Al-conditioned (AlCl-, Al, and Al-) membranes. The morphology of gypsum, the role of Al species on Ca adsorption during gypsum scaling, and the interactions between gypsum crystals and Al-conditioned membranes were investigated.
View Article and Find Full Text PDFACS ES T Water
January 2025
Department of Civil Engineering, The University of British Columbia, 6250 Applied Sciences Lane, Vancouver, British Columbia V6T 1Z4, Canada.
The present study evaluated the performance of a full-scale gravity-driven membrane filtration system with passive hydraulic fouling control (PGDMF) for drinking water treatment in a small community over a 3-year period. The PGDMF system consistently met the design flow and regulated water quality/performance parameters (i.e.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!