This paper has three purposes. (1) To verify an error formula from which the maximal precision in derivatives obtained from noisy measurement data can be calculated. The formula is verified by comparison with the resulting noise in derivatives obtained by local least squares polynomial fitting. It is also verified that differentiation by Fourier series expansion gives noise exceeding the minimum value according to the error formula. (2) An index called the "Relative Noise Amplification" (RNA) is introduced. For an arbitrary differentiating filter it is defined as the noise transmission of the filter divided by the minimal noise transmission according to the above mentioned error formula. When the filter produces unbiased estimates the value of the RNA always exceeds one. The RNA can be used as a quality index for differentiating filters. The filter with the smallest value on the RNA also has the smallest amount of noise superimposed on the calculated derivatives provided the input noise is white and additive. (3) The bandwidth and the Relative Noise Amplification of differentiating filters obtained by local least squares polynomial fitting are presented. The 0th, 1st and 2nd order derivatives have been investigated for polynomials up to 8th order. These results can be used for the determination of suitable filter parameters in various applications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0021-9290(82)90082-3DOI Listing

Publication Analysis

Top Keywords

error formula
12
noise
8
local squares
8
squares polynomial
8
polynomial fitting
8
noise transmission
8
differentiating filters
8
derivatives
5
filter
5
precision limits
4

Similar Publications

Aim: Development and optimization of raloxifene hydrochloride loaded lipid nanocapsule hydrogel for transdermal delivery.

Method: A 3 Box-Behnken Design and numerical optimization was performed to obtain the optimized formulation. Subsequently, the optimized raloxifene hydrochloride loaded lipid nanocapsule was developed using phase inversion temperature and characterized for physicochemical properties.

View Article and Find Full Text PDF

Re-locative guided search optimized self-sparse attention enabled deep learning decoder for quantum error correction.

Sci Rep

January 2025

Department of Mathematics, School of Advanced Sciences, VIT-AP University, Besides AP Secretariate, Amaravati, Andhra Pradesh, 522237, India.

Heavy hexagonal coding is a type of quantum error-correcting coding in which the edges and vertices of a low-degree graph are assigned auxiliary and physical qubits. While many topological code decoders have been presented, it is still difficult to construct the optimal decoder due to leakage errors and qubit collision. Therefore, this research proposes a Re-locative Guided Search optimized self-sparse attention-enabled convolutional Neural Network with Long Short-Term Memory (RlGS2-DCNTM) for performing effective error correction in quantum codes.

View Article and Find Full Text PDF

The ICH E9 addendum on estimands in clinical trials provides a framework for precisely defining the treatment effect that is to be estimated, but says little about estimation methods. Here, we report analyses of a clinical trial in type 2 diabetes, targeting the effects of randomized treatment, handling rescue treatment and discontinuation of randomized treatment using the so-called hypothetical strategy. We show how this can be estimated using mixed models for repeated measures, multiple imputation, inverse probability of treatment weighting, G-formula, and G-estimation.

View Article and Find Full Text PDF

To analyze the refractive accuracy of a novel swept-source optical coherence biometer (SS-OCT), that uses individual refractive indices to measure axial length, in short and long eyes implanted with monofocal intraocular lenses (IOLs). This retrospective comparative study considered eyes with short axial length (AL) (< 22.5 mm) or long AL (> 26 mm) bilaterally implanted with the Acrysof IQ monofocal IOL.

View Article and Find Full Text PDF

Background: The use of iodinated contrast-enhancing agents in computed tomography (CT) improves the visualization of relevant structures for radiotherapy treatment planning (RTP). However, it can lead to dose calculation errors by incorrectly converting a CT number to electron density.

Purpose: This study aimed to propose an algorithm for deriving virtual non-contrast (VNC) electron density from dual-energy CT (DECT) data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!