Blink reflex in facial-hypoglossal anastomosis.

Arch Psychiatr Nervenkr (1970)

Published: August 1978

The blink reflex was investigated in two patients after a facial-hypoglossal anastomosis had been performed. In each case the first component of the blink reflex could be demonstrated with normal latency on the operated side after ipsilateral supraorbital stimulation. These findings give further evidence that the first component of the blink reflex is not monosynaptic in nature. The second component of the blink reflex was distinctly retarded in the first case and was not seen at all in the second case. The second component of the blink reflex is influenced strongly by alteration of the intrabulbar and efferent part of the reflex circuits; it shows some correlation with voluntary motor activity.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF00343302DOI Listing

Publication Analysis

Top Keywords

blink reflex
24
component blink
16
facial-hypoglossal anastomosis
8
second component
8
case second
8
blink
6
reflex
6
reflex facial-hypoglossal
4
anastomosis blink
4
reflex investigated
4

Similar Publications

Background: Trigeminal neuralgia is a disease characterized by severe facial pain that significantly reduces patients quality of life. Trigeminal neuralgia is subcategorized as idiopathic, classic or secondary. Magnetic resonance imaging is the basis for classification, but neurophysiological tests are also used.

View Article and Find Full Text PDF

Blink-related oscillations (BROs) are newly discovered neurophysiological brainwave responses associated with spontaneous blinking, and represent environmental monitoring and awareness processes as the brain evaluates new visual information appearing after eye re-opening. BRO responses have been demonstrated in healthy young adults across multiple task states and are modulated by both task and environmental factors, but little is known about this phenomenon in aging. To address this, we undertook the first large-scale evaluation of BRO responses in healthy aging using the Cambridge Centre for Aging and Neuroscience (Cam-CAN) repository, which contains magnetoencephalography (MEG) data from a large sample ( = 457) of healthy adults across a broad age range (18-88) during the performance of a simple target detection task.

View Article and Find Full Text PDF

Flexible Eyelid Pressure and Motion Dual-Mode Sensor Using Electric Breakdown-Induced Piezoresistivity and Electrical Potential Sensing.

ACS Appl Mater Interfaces

January 2025

Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Lab, Beijing 100730, China.

Multiple ocular surface disorders are associated with the mechanical properties of the interface between the eyelid and cornea. Determining eyelid pressure is vital for diagnosing and preventing these disorders. However, current measurements rely on flat piezoresistive pressure sensor arrays that lack eye-motion sensing capabilities, resulting in discomfort and measurement inaccuracies.

View Article and Find Full Text PDF

Here a bioengineered platform is introduced to investigate adverse effects of environmental materials on the human cornea. Using primary cells, this system is capable of reproducing the differentiated corneal epithelium and its underlying stroma in the human eye, which can then be treated with externally applied solid, liquid, or gaseous substances in a controlled manner and under physiologically relevant conditions. The proof-of-principle of how this system can be used to simulate human ocular exposure to different classes of environmental toxicants for direct visualization and quantitative analysis of their potential to induce acute corneal injury and inflammation is demonstrated.

View Article and Find Full Text PDF

The present study introduces the idea of a novel fluorescence-based imaging technique combined with a microfluidic platform that enables a precise control of dark transient state populations of fluorescent probes flowing over a uniform, top flat supergaussian excitation field with a constant flow rate. To demonstrate the imaging capability of the proposed detection method, numerical simulations have been performed by considering laser, microscope and flow parameters of experimental setup together with photophysical model and electronic transition rates of fluorescent dyes. As an output data to be assessed, fluorescence image data is simulated numerically for bromine-free carboxyfluorescein and its brominated derivatives having different numbers of bromine atoms.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!