The tapered Lippes Loop D (LLD) is compared to the standard LLD to evaluate efficacy and termination events. The tapered device was designed with the intention of lowering the expulsion rate below the rate for women with standard Lippes Loops. The two devices were randomly assigned to 989 women in two studies. Expulsion rates for the tapered device were lower at six months (p less than 0.10) and at 12 months (p less than 0.05). When the women were divided into groups by uterine measurement, the differences continued to be significant for women with larger uteri but not for those with smaller uteri. Comparison of other pertinent event rates showed no significant differences. Analysis of the data indicates that the tapered LLD represents an improvement in expulsion rates over the standard LLD.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0010-7824(82)90052-xDOI Listing

Publication Analysis

Top Keywords

lippes loop
12
tapered lippes
8
standard lld
8
tapered device
8
expulsion rates
8
tapered
5
comparison lippes
4
loop tapered
4
loop intrauterine
4
intrauterine devices
4

Similar Publications

Background: Intrauterine devices are a widely used method of contraception worldwide. These devices are reliable, cost-effective, long-acting, and reversible. Their placement in the uterus is usually simple and safe.

View Article and Find Full Text PDF

This case report discusses a 77-year-old female patient who presented to an outpatient clinic with urinary symptoms and recurrent UTIs. Imaging revealed a foreign body, which was later confirmed as a retained intrauterine device (IUD) that had caused a vesicouterine fistula (VUF). The patient had a medical history of cervical cancer treated with radiation therapy, during which her IUD's string could not be located, leading to the decision to proceed with radiation therapy without removing the IUD.

View Article and Find Full Text PDF

Spontaneously Expelled Lippes Loop IUD After 40 Years of Use: A Case Report and Review of the Literature.

Int Med Case Rep J

July 2022

Department of Public Health, Institute of Health Sciences, Wollega University, Nekemte, Ethiopia.

Objective: Intrauterine devices are a widely used method of contraception worldwide. These devices are reliable, cost-effective, long-acting, and reversible. Their placement in the uterus is usually simple and safe.

View Article and Find Full Text PDF

Background And Objectives: To compare the efficacy of 3 different techniques for prevention of adhesion reformation after hysteroscopic adhesiolysis in patients with moderate-to-severe intrauterine adhesions. Short-term assisted reproductive outcomes were also compared.

Study Design: Total of 72 cases were randomized to Lippes loop intrauterine device (IUD) only, IUD plus a new crosslinked hyaluronan (NCH) gel, or NCH gel only following hysteroscopic adhesiolysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!