Fifty-five patients with brain lesions were examined by computed tomography (CT) after two doses of contrast medium: a bolus injection of 65% meglumine diatrizoate, 1 ml/kg, and a bolus injection of 65% meglumine diatrizoate, 1.5 ml/kg, in combination with an infusion of 250 ml meglumine iodamide containing 110 mg I/ml. The studies were usually performed 2 days apart and were analyzed by three radiologists. In 25 patients, one or more of the radiologists changed the diagnosis or the number or size of the lesions when the two scans were observed separately. In three patients, the primary tumor or metastases were seen in the study performed after the higher dose only, and, in two other patients having cerebral metastases, a greater number of metastases were detected in the high dose study. The lower dose containing 15 to 31 g iodine (306 mg iodine/kg) seems to be inadequate in CT of the brain.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00004728-198202000-00007DOI Listing

Publication Analysis

Top Keywords

contrast medium
8
bolus injection
8
injection 65%
8
65% meglumine
8
meglumine diatrizoate
8
diatrizoate ml/kg
8
high contrast
4
dose
4
medium dose
4
dose brain
4

Similar Publications

Dust emissions from open-pit mining pose a significant threat to environmental safety and human health. Currently, the range of dust suppressants used in coal mining is limited, often failing to account for their suitability across various stockpiles. This oversight results in poor infiltration after application, leading to insufficient crust formation and reduced durability.

View Article and Find Full Text PDF

Xanthomonas citri pv. malvacearum (Xcm) associated with bacterial blight disease is a significant and widespread pathogen affecting cotton worldwide. The excessive use of harmful chemicals to control plant pathogens has exerted a negative impact on environmental safety.

View Article and Find Full Text PDF

Contrast-enhanced US of High-Risk Indeterminate Focal Liver Observations Categorized as LR-4 or LR-M at CT/MRI.

Radiology

January 2025

From the Department of Radiology, Thomas Jefferson University Hospital, 132 S 10th St, 763G Main Bldg, Philadelphia, PA 19107 (A.L., C.K.Y.E., T.S.X., S.K.R., C.E.W., K.B., J.R.E., F.F.); Division of Internal Medicine, Hepatobiliary and Immunoallergic Diseases, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy (F.P.); Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy (F.P.); University of California San Diego, San Diego, Calif (Y.K.); University of Calgary, Calgary, Canada (A.M.K., S.R.W.); Einstein Medical Center, Philadelphia, Pa (S.K.R.); Vanderbilt University, Nashville, Tenn (V.P.); Stanford University, Stanford, Calif (A.K.); UT Southwestern Medical Center, Dallas, Tex (D.T.F.); Department of Visceral Surgery and Medicine, Bern University Hospital, University of Bern, Bern, Switzerland (A.B., I.P.R.); Department of Imaging Sciences, School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, United Kingdom (P.S.S.); and Department of Radiology, King's College Hospital, London, United Kingdom (P.S.S.).

Background Indeterminate focal liver observations in patients at risk for hepatocellular carcinoma (HCC) may require invasive biopsy or follow-up, which could lead to delays in definitive categorization and to postponement of treatment. Purpose To examine clinical effect of contrast-enhanced US (CEUS) in participants with high-risk indeterminate liver observations categorized as Liver Imaging Reporting and Data System (LI-RADS) category LR-4 (probably HCC) or LI-RADS category LR-M (probably or definitely malignant but not HCC specific) at CT or MRI. Materials and Methods This was a secondary analysis of a prospective international multicenter validation study for CEUS LI-RADS (January 2018 to August 2021).

View Article and Find Full Text PDF

Aims To evaluate the utility of unenhanced spectral imaging, electron density (ED) and overlay electron density (OED) images for assessing pulmonary embolisms in patients with suspected or confirmed acute pulmonary embolism (APE). Background Multiple spectral images can be extrapolated from spectral detector CT (SDCT), ED and OED images. ED and OED images are highly sensitive to moisture-rich tissues.

View Article and Find Full Text PDF

Background And Purpose: Prolonged length of stay (LOS) following a stroke is associated with unfavorable clinical outcomes. Factors predicting LOS in medium vessel occlusion (MeVO), impacting up to 40% of acute ischemic stroke (AIS) cases, remain underexplored. This study aims to investigate the predictors of LOS in AIS-MeVO.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!