A fluorescent immunoassay based on the correlation of fluctuations in particle number measures the amount of tagged species bound to micrometer-sized beads and is insensitive to background fluorescence. Without separation steps, a competitive assay can resolve I nanogram of gentamicin per milliliter from a total sample volume of only 10 microliters.

Download full-text PDF

Source
http://dx.doi.org/10.1126/science.7015511DOI Listing

Publication Analysis

Top Keywords

fluorescent immunoassay
8
homogeneous fluorescent
4
immunoassay fluorescent
4
immunoassay based
4
based correlation
4
correlation fluctuations
4
fluctuations particle
4
particle number
4
number measures
4
measures amount
4

Similar Publications

Simultaneous measurement of fentanyl, fentanyl analogues and other drugs of abuse by multiplex bead assay.

Toxicol Mech Methods

January 2025

Centers for Disease Control and Prevention, Division of Science Integration, Risk Evaluation Branch, National Institute for Occupational Safety and Health, Cincinnati, OH, USA.

Quantification of illicit drugs and controlled substances, in urine or as surface contamination, is often performed using expensive analytical techniques such as liquid chromatography with tandem mass spectrometry (LC-MS/MS). A time and cost-effective semi-quantitative surface-wipe and urine screening multiplex immunoassay for fentanyl and its analogues was developed in this investigation. We previously created a surface wipe multiplex immunoassay for methamphetamine, caffeine, cocaine, tetrahy-drocannabinol (THC) and oxycodone.

View Article and Find Full Text PDF

An integrated immunofluorescent detection system for automated and sensitive protein quantification based on a microfluidic flow cytometry platform.

Anal Chim Acta

March 2025

Holosensor Medical Technology Ltd, Room 12, No. 1798, Zhonghuayuan West Road, Yushan Town, Suzhou, 215000, China; Department of Veterinary Medicine, University of Cambridge, Cambridge, UK. Electronic address:

Rapid and sensitive protein detection methods are of benefit to clinical diagnosis, pathological mechanism research, and infection prevention. However, routine protein detection technologies, such as enzyme-linked immunosorbent assay and Western blot, suffer from low sensitivity, poor quantification and labourious operation. Herein, we developed a fully automated protein analysis system to conduct fast protein quantification at the single molecular level.

View Article and Find Full Text PDF

MUC1 and glycan probing of CA19-9 captured biomarkers from cyst fluids and serum provides enhanced recognition of ovarian cancer.

Sci Rep

January 2025

Department of Life Technologies, Division of Biotechnology, University of Turku, Medisiina D, 5th floor, Kiinamyllynkatu 10, 20520, Turku, Finland.

Glycosylation changes of circulating proteins carrying the CA19-9 antigen may offer new targets for detection methods to be explored for the diagnosis of epithelial ovarian cancer (EOC). Search for assay designs for targets initially captured by a CA19-9 antigen reactive antibody from human body fluids by probing with fluorescent nanoparticles coated with lectins or antibodies to known EOC associated proteins. CA19-9 antigens were immobilized from ascites fluids, ovarian cyst fluids or serum samples using monoclonal antibody C192 followed by probing of carrier proteins using anti-MUC16, anti-MUC1 and, anti STn antibodies and seven lectins, all separately coated on nanoparticles.

View Article and Find Full Text PDF

Crystal Structures of Antigen-Binding Fragment of Anti-Osteocalcin Antibody KTM219.

Int J Mol Sci

January 2025

Department of Applied Biology, Faculty of Textile Science and Technology, Shinshu University, Ueda 386-8567, Nagano, Japan.

Osteocalcin is a useful biomarker for bone formation and bone-related diseases. KTM219 is an anti-osteocalcin C-terminal peptide antibody. The single-chain variable region (scFv) and antigen-binding fragment (Fab) of KTM219 are applicable to the Quenchbody (Q-body) immunoassay.

View Article and Find Full Text PDF

Background/objectives: Systemic autoimmune rheumatic diseases (SARDs) pose diagnostic challenges, particularly in pediatric populations, due to their diverse presentations and overlapping symptoms. This study aimed to evaluate the diagnostic concordance between indirect immunofluorescence (IIF) at different dilution levels (1/80 and 1/640) and immunoblot findings for anti-centromere antibody (ACA) positivity. Additionally, the clinical significance of ACA positivity and its association with SARDs in pediatric patients was assessed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!