Surface smoothness is an important requirement for restorative materials. Recently, restorative materials claimed to be inherently smooth in surface characteristics have been developed. Matrix-formed and finished surfaces of five new microfill restorative materials were compared with two composite resins, an acrylic resin and a silicate cement by means of scanning electron microscopy. The results of this investigation indicated that the matrix-formed surfaces of all the restorative materials studied were not altogether perfect. Polishing using sandpaper and cuttlefish discs produced a very smooth surface finish in the new microfill restorative materials, Estic microfill, Estilux microfill, Isopast, Isolux and Silar which was comparable to that of the acrylic resin, Sevriton. The composite resins, Adaptic and Estilux exhibited the worst surface finish and the silicate cement, Bio-trey was intermediate. Finishing, using other finer polishing devices on four of the materials produced a further improvement in the surface finish.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1365-2842.1982.tb00536.xDOI Listing

Publication Analysis

Top Keywords

restorative materials
24
surface finish
16
microfill restorative
12
finish microfill
8
scanning electron
8
smooth surface
8
composite resins
8
acrylic resin
8
silicate cement
8
materials
7

Similar Publications

Background: In recent years, there have been suggestions for new restorative strategies that aim to effectively utilize modern adhesive technologies and protect the remaining intact tooth structure. This study was conducted to evaluate the clinical performance of fiber reinforced resin composites in restoring Class II MOD cavities over 18 months.

Methods: Forty-five participants with class II MOD cavities were randomly enrolled.

View Article and Find Full Text PDF

Periapical bone edema volume in 3D MRI is positively correlated with bone architecture changes.

Insights Imaging

January 2025

Diagnostic and Interventional Radiology, University Hospital of Zurich, University Zurich, Zurich, Switzerland.

Objectives: To compare and correlate bone edema volume detected by 3D-short-tau-inversion-recovery (STIR) sequence to osseous decay detected by a T1-based sequence and conventional panoramic radiography (OPT).

Materials And Methods: Patients with clinical evidence of apical periodontitis were included retrospectively and received OPT as well as MRI of the viscerocranium including a 3D-STIR and a 3D-T1 gradient echo sequence. Bone edema was visualized using the 3D-STIR sequence and periapical hard tissue changes were evaluated using the 3D-T1 sequence.

View Article and Find Full Text PDF

Joint endoprosthetics is one of the most successful surgical-orthopedic procedures worldwide, enabling pain reduction and complete restoration of mobility. In the Federal Republic of Germany, around 400,000 joint endoprostheses, hip and knee joints are currently implanted every year ( https://www.eprd.

View Article and Find Full Text PDF

This study aimed to compare the bonding efficacy three bioactive self-adhesive restorative systems to dentin. A total of 80 permanent human molars were utilized in this study. The occlusal enamel was removed to exposed mid-coronal dentin; 40 molars were used for microshear bond strength testing, while the remaining molars were used for micromorphological analysis of restoration/dentin interface.

View Article and Find Full Text PDF

Robot-assisted Endodontic Retreatment: A Case Report with Clinical Considerations.

J Endod

January 2025

State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China; Department of Cariology and Endodontics, School and Hospital of Stomatology, Wuhan University, Wuhan, China. Electronic address:

Introduction: Fiber posts present significant challenges for nonsurgical endodontic retreatment, as improper removal may result in iatrogenic root perforation or even root fracture. Recently, robotic technology has attracted considerable attention in dentistry and active dental robotic (ADR) systems can perform procedures based on preset instructions, minimizing reliance on the dentist's experience. This case report describes the application of an ADR system for fiber post removal through an existing zirconia crown.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!