A prospective study was performed in 30 children under 3 years of age to compare the cardiovascular effects of a nonionic contrast material of low osmolality, metrizamide, with those of a conventional ionic contrast material, meglumine sodium diatrizoate. Left ventricular end-diastolic pressure, left ventricular peak systolic pressure, heart rate, echocardiographically obtained end-diastolic and end-systolic dimension, and blood chemistries were obtained before and after angiography. Neither contrast material changed serum sodium, potassium, or creatinine levels. However, serum osmolality rose significantly following injection of diatrizoate, but not metrizamide. Both end-diastolic and end-systolic dimensions increased after diatrizoate injection. However, end-diastolic dimension was unchanged and end-systolic dimension fell after metrizamide infusion. Both contrast materials raised left ventricular peak systolic pressure and left ventricular end-diastolic pressure after injection; the magnitude of these pressure changes was the same for both agents. Heart rate increased with diatrizoate to a significantly greater degree than with metrizamide. There was no difference in the quality of radiographic opacification. It is concluded that although the effects on intracardiac pressures are similar for both contrast materials, metrizamide may be advantageous in the critically ill infant because it causes a smaller increase in osmolality, fewer changes in cardiac dimensions, and a reduced heart rate challenge.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1148/radiology.148.3.6878685 | DOI Listing |
J Clin Hypertens (Greenwich)
January 2025
Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China.
This study aimed to investigate the correlation of the increased volume index of epicardial adipose tissue (EAT) and left ventricular hypertrophy (LVH) in patients with Hypertension (HTN). A total of 209 HTN patients and 50 healthy controls, who underwent cardiovascular magnetic resonance (CMR) at two medical centers in China between June 2015 and October 2024, were enrolled for this study. Postprocessing and imaging analysis were conducted and EAT measurements were performed.
View Article and Find Full Text PDFCirc Cardiovasc Imaging
January 2025
Multimodality Cardiac Imaging Section, IRCCS Policlinico San Donato, Milan, Italy (L.T., G.D., M.L., A.C.).
Iran J Basic Med Sci
January 2025
Molecular Medicine Research Center, Biomedicine Institute, Tabriz University of Medical Sciences, Tabriz, Iran.
Objectives: Ischemia/reperfusion (IR)-induced ventricular arrhythmia, which mainly occurs after the opening of coronary artery occlusion, poses a clinical problem. This study aims to investigate the effectiveness of pretreatment with coenzyme Q (CoQ) in combination with mitochondrial transplantation on IR-induced ventricular arrhythmias in aged rats.
Materials And Methods: Myocardial IR induction was performed by left anterior descending coronary artery occlusion for 30 min, followed by re-opening for 24 hr.
Malawi Med J
January 2025
Department of Paediatrics, College of Medicine, University of Nigeria Ituku/Ozalla and University of Nigeria Teaching Hospital Ituku/Ozalla, Enugu, Enugu State, Nigeria.
Background: Children with Tetralogy of Fallot (TOF) usually present with right heart abnormalities, however much is not known if these children presents with left ventricular dysfunction.
Objectives: This article is aimed to ascertain the left ventricular function of children with TOF compared with those without any congenital heart disease. It also elicits the correlation if any, between left ventricular mass and descending aorta blood flow.
Eur Heart J Case Rep
January 2025
Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka 589-8511, Japan.
Background: The initial outcomes of transcatheter aortic valve replacement in patients with left ventricular outflow tract calcification are poor. Furthermore, balloon-expandable transcatheter aortic valve replacement is associated with an increased risk of annular rupture, and self-expandable transcatheter aortic valve replacement is associated with worse post-operative residual paravalvular leakage grades. Therefore, developing an optimal method for transcatheter aortic valve replacement for patients with left ventricular outflow tract calcification is desirable.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!