In a recent report the Maryland statewide health data base, which is derived from "face sheet" data, was used to determine the appropriateness of permanent pacemaker insertion. In the present study the same indications were utilized and both the complete medical records and the face sheet were reviewed for those patients who had been classified as having permanent pacemakers inserted for inappropriate or questionable reasons. In 32 hospitals, 75% of the records were reviewed (610 of 817 patients). Although coded as having received permanent pacemakers, 16% had received temporary pacemakers, battery change, and the like. Diagnoses justifying permanent pacemaker insertion had been omitted in 53% of the face sheet s, and coding errors were found in 39%. Although none of the 610 medical records reviewed had a valid indication for permanent pacemaker insertion listed on the face sheet, complete medical record review demonstrated valid indications in 95%. Inherent difficulties arise in attempting to list rigid indications for permanent pacemaker insertion. The face sheet does not provide adequate data for assessing the appropriateness of permanent pacemaker insertion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0002-9149(83)80023-xDOI Listing

Publication Analysis

Top Keywords

permanent pacemaker
24
pacemaker insertion
20
face sheet
16
health data
8
permanent
8
appropriateness permanent
8
complete medical
8
medical records
8
permanent pacemakers
8
records reviewed
8

Similar Publications

Transcatheter aortic valve replacement (TAVR) in patients with severe aortic stenosis and raphe-type bicuspid aortic valve (BAV) is still associated with poor outcomes in terms of increased risk of paravalvular regurgitation, stroke, and permanent pacemaker implantation. There is no definitive consensus on the optimal sizing method for prosthesis selection in this setting. The LIRA method is a supra-annular tailored sizing method specifically designed for bicuspid anatomy that might increase accuracy of prosthesis choice in BAV patients and improve TAVR outcomes.

View Article and Find Full Text PDF

Pulmonary thromboembolism (PTE) is the third most common cause of acute cardiovascular disease, which can lead to high morbidity and mortality if left untreated. Anatomical and electrophysiological variations and obesity may complicate timely diagnosis and delay required management. While computed tomography pulmonary angiography (CTPA) remains the most accurate diagnostic tool, initial assessments using electrocardiography (ECG) or echocardiography can be helpful in early suspicion.

View Article and Find Full Text PDF

Background: Aortic stenosis (AS) remains a prevalent and serious global health concern, exacerbated by an aging population worldwide. This valvular disease, when symptomatic and without appropriate intervention, severe AS can drastically reduce life expectancy. In our systematic review and -analysis, we aim to synthesize available evidence to guide clinical decision-making by comparing the performance of TAVR and SAVR, specifically in patients with severe AS and a small aortic annulus.

View Article and Find Full Text PDF

There is an increased risk of cardiac complications in COVID-19 among patients with pre-existing comorbidities due to their existing pro-inflammatory status. The manifestation of complete heart block has been evidenced as transient and in no need of intervention. This case presents a previously healthy woman who was diagnosed with SARS-CoV-2 infection and complete heart block; she underwent permanent dual-chamber pacemaker implantation after successful treatment and a negative COVID-19 test.

View Article and Find Full Text PDF

Pathology-Independent Expansion of Indications for Rapid-Deployment Aortic Valve Replacement: Midterm Outcomes.

Thorac Cardiovasc Surg

January 2025

Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea.

Background:  This study evaluated the midterm outcomes of rapid deployment aortic valve replacement (RDAVR) performed regardless of pathology for various aortic valve diseases at a single center.

Methods:  Of the 344 patients who underwent RDAVR using Edwards INTUITY during the study period at our institution, 176 had bicuspid valve diseases (51.2%), 20 had pure aortic regurgitation (5.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!