Measurements of patient serum complement components C3 and C4 are useful indicators of complement consumption in immune complex diseases. A fluorometric quantitative immunofluorescence system was evaluated in terms of measuring these complement components, and the results were compared with those of radial immunodiffusion assays. For comparison of the two systems, 232 patient sera were evaluated for C3, and 202 specimens were tested for C4. Analysis of the data by linear regression indicated a proportional difference between the methods. C3 and C4 concentrations measured by the fluorometric method were lower than those measured by radial immunodiffusion, especially concentrations exceeding the normal ranges. In detecting lower concentrations (less than 120 mg/dl for C3 and less than 25 mg/dl for C4), the two methods showed better agreement. Each assay system was reproducible and could be used to evaluate changes that occur in concentrations of complement components during therapeutic treatment. However, the ease in processing a large volume of specimens and the short time needed to complete the assay are advantages that make the fluorometric method more suitable than radial immunodiffusion for use in a large clinical laboratory.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC272343PMC
http://dx.doi.org/10.1128/jcm.16.2.271-275.1982DOI Listing

Publication Analysis

Top Keywords

radial immunodiffusion
16
complement components
16
fluorometric method
12
immunodiffusion assays
8
complement
5
comparison fluorometric
4
radial
4
method radial
4
immunodiffusion
4
assays determination
4

Similar Publications

Comparison of radial immunodiffusion, turbidimetric immunoassay, and Brix refractometry for determining bovine colostrum quality.

JDS Commun

November 2024

Department of Population Medicine and Diagnostic Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853.

Determining the concentration of IgG in colostrum is critical for assessment of colostrum quality. On-farm use of a Brix refractometer to estimate colostrum IgG concentration is widespread, whereas radial immunodiffusion (RID) is the laboratory reference method. Turbidimetric immunoassay (TIA) might offer an alternative method to quantify IgG in colostrum, but the agreement with RID, as well as critical thresholds to determine high-quality colostrum, remain uncertain.

View Article and Find Full Text PDF

Collaborative study on the cross-reactivity of two influenza B viral components in single radial immunodiffusion assay using quadrivalent influenza vaccines in Japan from 2015/16 to 2021-22 influenza season.

Biologicals

November 2024

Department of Virology III, Gakuen 4-7-1, Musashi-Murayama, Tokyo, 208-0011, Japan; Center for Quality Management Systems, Gakuen 4-7-1, Musashi-Murayama, Tokyo, 208-0011, Japan; Research Center for Influenza and Respiratory Viruses, National Institute of Infectious Diseases, Gakuen 4-7-1, Musashi-Murayama, Tokyo, 208-0011, Japan. Electronic address:

A quadrivalent influenza vaccine (QIV) has been available in Japan since the 2015/2016 influenza season. Single radial immunodiffusion (SRID) assays are currently used worldwide to measure the hemagglutinin (HA) content of influenza vaccine components because they are simple, accurate, and the regulatory requirement, ensuring consistency in manufacture for the HA content. However, the cross-reactivity of antisera against the two lineages of the influenza B virus (IFVB) may cause inaccurate quantification of HA content in QIVs using the SRID assay.

View Article and Find Full Text PDF

A Rapid Virus-Free Method for Producing Influenza HA Immunogen Needed for Preparation of Influenza Vaccine Potency Antisera Reagents.

Influenza Other Respir Viruses

October 2024

Division of Viral Products, Laboratory of DNA Viruses, Center for Biologics Evaluation and Research, Food and Drug Administration, Silver Spring, Maryland, USA.

Background: The potency of inactivated and recombinant influenza vaccines is measured using the single-radial immunodiffusion (SRID) assay. The strain-specific antigen and antibody potency reagents required for the assay are prepared and distributed by regulatory agencies to ensure vaccine standardization, but timely reagent production is always challenging. This poses unique concerns for rapid pandemic responses.

View Article and Find Full Text PDF

Immune competence is a key factor in the health and resilience of dairy ruminants. The aim of this study was to study IgG concentration in serum shortly after birth and in colostrum of lactating animals as proxy of passive immune transfer and colostrum quality, respectively, and thus provide new health and resilience indicators for selection. Data from 424 female kids and 203 primiparous goats, reared on an INRAE experimental farm, were analyzed.

View Article and Find Full Text PDF

In the United States, 19 allergen extracts of different specificities are standardized, which means that their potencies are determined in comparison to a US reference standard. For cat allergen extracts, potency is determined by measuring Fel d 1 content expressed in in Fel d 1 units, and with a unitage that correlates with skin test reactions (bioequivalent allergy units or BAU). Currently, Fel d 1 content is measured with a radial immunodiffusion (RID) assay that uses polyclonal sheep antisera to detect the allergenic protein by producing a white precipitin line in agar gel.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!