A cardiorespiratory monitoring system allows the measurement of FAECO2 and FECO2 in the expired air of the patient at the mouth (endtidal CO2) and in a mixing box. From these parameters, combined with the measured PACO2, the alveolo-expired (DuA = PECO2/PAECO2) and alveolar-arterial (Dua = PAECO2/PACO2) ductances which assimilate the respiratory system to a two-stage exchanger have brought about a lot of valuable information 1. DuA improves by 20% in 20 patients after removal of bronchial obstruction (p < 0.001) and by 9% in 7 intubated patients after tracheotomy (p < 0.02). DuA falls by 15% (p < 0.001) in 10 patients with hypocapnia (PaCO2 = 28 mmHg) after a dead space adjunction with the aim of normalizing PaCO2 (paCO2 = 35 mmHg). 2. Dua falls by 33% in six patients after pulmonary embolism, proved by angiography (p 0.001) by 9% in 34 patients after 30 min of pure oxygen breathing (p 0.001). On the other hand, inthe absence of clinical or radiological pulmonary edema, in increases by 19% in 38 patients with hypervolemia after diuresis (furosemide) (p < 0.001). Thus since DuACO2 varies with anatomical dead space and the air distribution disorder, DuaCO2 evolves according to the disorders of the blood distribution and arterial-alveolar diffusion. The determination of these coefficients, in the absence of significant changes in the arterial blood gases, helps the diagnosis, guides the early treatment and allows for the monitoring of its efficiency.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF01687162DOI Listing

Publication Analysis

Top Keywords

dua falls
8
0001 patients
8
paco2 mmhg
8
dead space
8
patients
6
dua
5
0001
5
continuous monitoring
4
monitoring co2
4
co2 ductances
4

Similar Publications

Prevalence of Reduced Vision among UK Elderly Drivers: The Bridlington Eye Assessment Project (BEAP)-A Cross-Sectional Study.

J Ophthalmol

September 2022

Department of Ophthalmology and Vision Sciences, Division of Clinical Neurosciences, B Floor, EENT Centre, Queen's Medical Centre, Nottingham University Hospitals and University of Nottingham, Nottingham, UK.

Self-assessment of driving fitness is mandatory in the United Kingdom. A paucity of data on visual function among drivers exists. We report prevalence of elderly drivers below legal visual acuity (VA) standard from a population study (The Bridlington Eye Assessment Project (BEAP)) conducted from 2002 to 2006.

View Article and Find Full Text PDF

COVID-19 vaccination acceptance in Jambi City, Indonesia: A single vaccination center study.

Vacunas

June 2022

Puskesmas Putri Ayu, Jambi, Jl. Slamet Riyadi, Legok, Danau Tlk., Kota Jambi, Jambi 36121, Indonesia.

Background: Indonesia has not met its vaccination rate target, falling short of 25% in 2021. This study aims to assess all the contributing factors towards vaccine acceptance, hesitance, and refusal in a single vaccination center in Jambi, Indonesia.

Materials And Methods: We collected primary data from respondents directly through a structured questionnaire.

View Article and Find Full Text PDF

Yamuna is one of the main tributaries of the river Ganga and passes through Delhi, the national capital of India. In the last few years, it is considered one of the most polluted rivers of India. We carried out the analysis for the physiochemical and biological conditions of the river Yamuna based on measurements acquired at Palla station, Delhi during 2009-19.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!