Transmural concentration profiles of 125I-albumin in vivo were measured across the normal and balloon catheter-deendothelialized rabbit descending thoracic aorta as a function of time following intravenous injection. A tracer was injected 5 or 60 minutes after deendothelialization, and the animals were sacrificed after circulation times of 10, 30 or 60 minutes. The aorta was immediately excised and frozen flat between glass slides. Samples were serially sectioned parallel to the intimal surface in a refrigerated microtome, washed with trichloroacetic acid (TCA), and counted. Relative tissue concentration profiles of TCA-precipitable radioactivity from the media of control animals showed entry from both luminal and adventitial sides, as previously found with conscious normal rabbits, but spatial gradients at both luminal and medial-adventitial borders were less steep. Relative concentration levels in ballooned animals were 10- to 40-fold higher than in controls, and the profiles were flatter. Uptake rates at equivalent circulation times were greater in experiments initiated 60 minutes, as compared with 5 minutes, after deendothelialization, suggesting that progressive medial edema may have occurred following balloon injury. These results show that the intact endothelium is the dominant mass transfer resistance for 125I-albumin transport across the aortic wall. The data also suggest that the incomplete monolayer of platelets adherent to the subendothelium after balloon deendothelialization is not a substantial resistance to transport, as compared to that of the media, and that convection plays a more important role than diffusion for 125I-albumin transport across the deendothelialized aortic wall.

Download full-text PDF

Source
http://dx.doi.org/10.1161/01.atv.4.3.283DOI Listing

Publication Analysis

Top Keywords

thoracic aorta
8
concentration profiles
8
minutes deendothelialization
8
circulation times
8
125i-albumin transport
8
aortic wall
8
transport
4
transport 125i-albumin
4
125i-albumin normal
4
normal deendothelialized
4

Similar Publications

Pseudoaneurysm of the descending aorta two decades after aortic coarctation repair: a case report.

J Cardiothorac Surg

January 2025

Department of Cardiovascular Surgery, West China Hospital of Sichuan University, 37# Guoxue Xiang, Chengdu, 610041, Sichuan, China.

Background: Pseudoaneurysm after coarctation of the aorta (CoA) repair is a rare but severe complication. Contributing factors may include infection, hypertension, aortic wall weakness, and turbulent blood flow at the repair site.

Case Presentation: A 35-year-old male presented with recurrent episodes of epistaxis and dizziness was admitted to the emergency department.

View Article and Find Full Text PDF

Aneurysm rupture is a life-threatening event, yet its underlying mechanisms remain largely unclear. This study investigated the fracture properties of the thoracic aneurysmatic aorta (TAA) using the symmetry-constraint Compact Tension (symconCT) test and compared results to native and enzymatic-treated porcine aortas' tests. With age, the aortic stiffness increased, and tissues ruptured at lower fracture energy [Formula: see text].

View Article and Find Full Text PDF

Background: Individuals harbouring pathogenic variants are at risk for aneurysms/dissections throughout the arterial tree. Based on prior reports of sex differences in thoracic aortic aneurysm/dissection, we investigated the sexual dimorphism for vascular events in variant-harbouring patients.

Methods: We analysed two large pedigrees comprising 84 individuals segregating pathogenic missense variants affecting the same p.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) is a common treatment for severe aortic stenosis (AS), but it carries the risk of severe complications, including device embolization. We present a case of a TAVR valve embolization into the left ventricular outflow tract (LVOT), diagnosed with transesophageal echocardiography (TEE) shortly after device deployment. The dislodged valve was successfully retrieved from the LVOT into the aorta, flattened, and stabilized with a thoracic endovascular aneurysm repair (TEVAR) stent, enabling the successful implantation of a new TAVR valve.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the differences between smooth muscle cells (SMCs) from two lineages in the proximal thoracic aorta, specifically the second heart field (SHF) and cardiac neural crest.
  • Researchers used advanced techniques like single-cell RNA sequencing and chromatin accessibility assays to analyze these cells in male mice, identifying distinct gene expressions in both lineages.
  • Findings reveal that SHF-derived SMCs have unique transcriptomic profiles that may influence their functions in thoracic aortic diseases, suggesting lineage-specific roles in vascular health.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!