We determined normal reference values from data on sera of 2099 outpatient children (ages one week to 14 years) at our institution. Using a continuous-flow instrument (SMAC, Technicon), we determined the following analytes in each serum sample: glucose, creatinine, uric acid, inorganic phosphorus, sodium, potassium, chloride, total CO2, iron, cholesterol, triglycerides, total protein, albumin, total bilirubin, creatine kinase, lactate dehydrogenase, alkaline phosphatase, aspartate aminotransferase, alanine aminotransferase, and calcium. The resulting data were coded and subsequently processed in an IBM 370 computer, and the reference values (3rd and 97th percentiles) were defined for each analyte. A two-way analysis of variance was also done to determine the influence of age and sex on results of these 20 biochemical tests.

Download full-text PDF

Source

Publication Analysis

Top Keywords

reference values
8
normal reference-intervals
4
reference-intervals biochemical
4
biochemical variables
4
variables healthy
4
healthy infants
4
infants children
4
children adolescents
4
adolescents determined
4
determined normal
4

Similar Publications

Background: Lymph node upstaging represents a quality criterion for standardized lymphadenectomy in lung cancer surgery. The aim of the study was to compare whether the quality of standardized lymphadenectomy in lung cancer surgery is comparable in minimally invasive (video-assisted thoracoscopic surgery) and the open approach (thoracotomy). Furthermore, factors associated with lymph node upstaging were assessed, as was its impact on overall survival and progression-free survival.

View Article and Find Full Text PDF

Background: The use of iodinated contrast-enhancing agents in computed tomography (CT) improves the visualization of relevant structures for radiotherapy treatment planning (RTP). However, it can lead to dose calculation errors by incorrectly converting a CT number to electron density.

Purpose: This study aimed to propose an algorithm for deriving virtual non-contrast (VNC) electron density from dual-energy CT (DECT) data.

View Article and Find Full Text PDF

Normal variations of myocardial T1, T2 and T2* values at 1.5 T cardiac MRI in sex-matched healthy volunteers.

Diagn Interv Imaging

January 2025

UFR Santé INSERM U1096, Rouen 76183, France; Department of Radiology and Medical Imaging (Cardiac Imaging Unit), CHU de Rouen Normandie, Hôpital Charles Nicolle, University of Rouen Normandie, Rouen 76000, France. Electronic address:

Purpose: The purpose of this study was to determine the normal variations of myocardial T1, T2, and T2* relaxation times on cardiac MRI obtained at 1.5 T in healthy, sex-balanced volunteers aged between 18 and 69 years.

Material And Methods: A total of 172 healthy volunteers were recruited prospectively.

View Article and Find Full Text PDF

Flavonoids are a key class of polyphenols, i.e., phytochemical compounds present in foods and beverages, which have been described as having health benefits in preventing several chronic diseases.

View Article and Find Full Text PDF

Introduction: Dermatomyositis (DM) is an uncommon idiopathic inflammatory myopathy resulting in characteristic patterns of cutaneous lesions and myositis. Observational evidence related to the disease is limited by small case cohorts. We aimed to evaluate the validity of specialist-specific diagnostic coding for DM in an outpatient clinical database.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!