Objective venous tinnitus. A case report.

J Laryngol Otol

Published: February 1984

A case of objective venous tinnitus with onset just after an operation for otosclerosis is presented. The maximum intensity of the tinnitus was measured at 38 db. SPL. The tinnitus disappeared after ligation of the internal jugular vein on the affected side. It is concluded that, even if objective tinnitus is uncommon compared with subjective tinnitus, it is important to elucidate its cause, because it is sometimes possible to cure the patient.

Download full-text PDF

Source
http://dx.doi.org/10.1017/s0022215100146407DOI Listing

Publication Analysis

Top Keywords

objective venous
8
venous tinnitus
8
tinnitus
6
tinnitus case
4
case report
4
report case
4
case objective
4
tinnitus onset
4
onset operation
4
operation otosclerosis
4

Similar Publications

Blood microsampling (BμS) has recently emerged as an interesting approach in the analysis of endogenous metabolites but also in metabolomics applications. Their non-invasive way of use and the simplified logistics that they offer renders these technologies highly attractive in large-scale studies, especially the novel quantitative microsampling approaches such as VAMs or qDBS. Herein, we investigate the potential of BµS devices compared to the conventional plasma samples used in global untargeted mass spectrometry-based metabolomics of blood.

View Article and Find Full Text PDF

Direct Axillary Artery Cannulation as Standard Perfusion Strategy in Minimally Invasive Coronary Artery Bypass Grafting.

J Cardiovasc Dev Dis

January 2025

Department of Cardiothoracic Surgery, Heart-Thorax Center, Klinikum Fulda, University Medicine Marburg, Campus Fulda, 36043 Fulda, Germany.

Objective: Cardiopulmonary bypass (CPB) via the right axillary artery (RAA) has become an alternative perfusion strategy, especially in complex aortic procedures. This study delineates our technique and outcome with direct axillary cannulation utilizing the Seldinger technique, which we adopted as the standard perfusion strategy in the sternum-sparing minimally invasive total coronary revascularization via left anterior thoracotomy (TCRAT) using CPB.

Methods: From November 2019 to December 2023, a total of 413 consecutive patients underwent nonemergent isolated coronary artery bypass grafting (CABG) via left anterior minithoracotomy on CPB with peripheral cannulation via the RAA and cardioplegic cardiac arrest, using this technique as a default strategy in the daily routine.

View Article and Find Full Text PDF

Background: Hemodialysis vascular access predisposes patients to exit-site infections (ESIs) and bloodstream infections (BSIs), resulting in significant morbidity and mortality. The objective was to characterize hemodialysis catheter-related (CR) ESIs and BSIs while considering potential factors associated with infection.

Methods: The study period was selected to coincide with new CR-infection prevention measures at the midpoint.

View Article and Find Full Text PDF

Objective: This study sought to evaluate the value of a CO field-flooding device in cardiopulmonary bypass (CPB) surgical procedures for congenital heart disease (CHD) performed via a right-side small incision approach.

Methods: Between April 2022 and December 2023, 234 children with simple CHD who underwent CPB via a right-side small incision approach were separated into a control group (n = 93) without the use of a CO field-flooding device and a treatment group (n = 141) in which this device was added to the traditional surgical manual exhaust. Demographic, perioperative, arterial blood gas (ABG), and laboratory test data were then compared between these groups of patients.

View Article and Find Full Text PDF

Objective: it was to evaluate the efficacy and safety of rapamycin-eluting stents at different doses in the treatment of coronary artery narrowing in miniature pigs.

Methods: a total of 20 miniature pigs were randomly assigned into four groups: S1 group (low-dose rapamycin-coated stent, 55 µg/mm), S2 group (medium-dose rapamycin-coated stent, 120 µg/mm), S3 group (high-dose rapamycin-coated stent, 415 µg/mm), and D0 group (bare metal stent). The stent size was 3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!