Twenty-four hour ambulatory electrocardiography was performed on 28 patients with aortic stenosis without significant coronary artery disease or aortic regurgitation. Compared to a control group of subjects with normal hearts proven by noninvasive and invasive testing, patients with aortic stenosis had higher (p = 0.0001) frequency of premature ventricular contractions (PVC) (3144 +/- 1425 versus 17 +/- 46) per 24 hours and higher (p = 0.001) prevalence of PVC presence (27 of 28 patients versus 39 of 101 normal), and complexity (19 of 28 patients versus 4 of 101 normal). Weak correlations of complexity with left ventricular end-diastolic pressure (r = 0.30) and ejection fraction (r = -0.25) were noted. No correlation of ventricular ectopic activity with peak systolic gradient, aortic valve area, or peak left ventricular systolic pressure was noted. Repeat 24-hour ambulatory electrocardiography performed on 13 patients three months after successful aortic valve replacement did not show significant effect of aortic valve replacement on PVC frequency or complexity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1378/chest.85.2.211 | DOI Listing |
Eur Heart J Cardiovasc Imaging
January 2025
Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.
Aims: This study evaluates whether multi-chamber myocardial deformation analysis using speckle tracking echocardiography (STE) can enhance validated current staging systems and improve risk stratification for patients with moderate-to-severe aortic stenosis (AS).
Methods And Results: We reanalyzed 2D, Doppler, and STE data obtained from two cohorts: derivation (654 patients, median age: 82 years; 51% men) and validation (237 patients, median age: 77 years; 55% men) with at least moderate AS (aortic valve area<1.5 cm2).
Eur J Cardiothorac Surg
January 2025
Department of Cardiac Surgery, University Hospital Quironsalud Madrid, Spain.
Objectives: The Ross procedure for aortic regurgitation (AR) and abnormal aortic valve morphologies is associated with an increased risk of autograft dilatation. Autograft support may ameliorate this problem. We analyzed the results for all haemodynamic lesions and the effect of autograft support.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.
Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.
Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.
Eur Heart J Case Rep
January 2025
Tehran Heart Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, North Kargar Ave, Tehran 1411713138, Iran.
Background: Since the transcatheter valve-in-valve (ViV) procedure was introduced in 2007, a few cases of infective endocarditis (IE) following the ViV procedure have been reported, which can be predisposed by older age, pre-existing medical conditions, and procedural techniques. Paravalvular abscesses constitute a rare complication of IE, resulting from extending IE beyond the valve annulus, less commonly caused by species. This complication is more common in prosthetic valves, particularly bioprosthetic valves.
View Article and Find Full Text PDFCJC Open
January 2025
Department of Cardiology, Royal North Shore Hospital, Sydney, Australia.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!