The aorta, right pulmonary artery and pulmonary trunk were measured from the 2-dimensional echocardiogram (2-D echo) of 110 normal subjects aged 1 day to 18 years. The vessel diameters were measured from the parasternal short-axis view, the suprasternal long-axis view and the suprasternal short-axis view. Measurements were made at end-systole and at end-diastole and in both an axial and lateral direction where possible. When analyzed with respect to body surface area (BSA), the echocardiographic measurements were linearly related to the square root of the BSA, and there was inequality of variance around the relation. To establish a range of normal values for each vessel dimension, a weighted regression analysis was used to produce estimates of the regression line and a set of tolerance intervals. The systolic vessel dimension was larger than the diastolic vessel dimension and the measurement of a vessel in an axial direction was larger than the measurement of the same vessel in a lateral direction. In general, when a vessel was measured in several views, the largest diameter was obtained using the view that imaged the vessel in cross section. These data on normal values for the echocardiographic measurement of the aorta and pulmonary arteries at different BSAs should be useful for identifying patients with abnormalities in arterial size and for the serial assessment of arterial size in children who have undergone surgical or medical therapy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0002-9149(84)90715-x | DOI Listing |
Ophthalmic Physiol Opt
January 2025
Robert O Curle Ophthalmology Suite, Institute for Regeneration and Repair, The University of Edinburgh, Edinburgh, UK.
Purpose: To determine whether imaging features derived from fundus photographs contain 3D eye shape information beyond that available from spherical equivalent refraction (SER).
Methods: We analysed 99 eyes of 68 normal adults in the UK Biobank. An ellipsoid was fitted to the entire volume of each posterior eye (vitreous chamber without the lens)-segmented from magnetic resonance imaging of the brain.
Port J Card Thorac Vasc Surg
January 2025
Thoracic surgeon, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milano, Italy.
The use of extracorporeal membrane oxygenation (ECMO) in surgery is expanding as the medical community started adopting it, with good results, for procedures with high risk of respiratory and hemodynamic instability. This technique provided the possibility to reduce the number of patients previously considered inoperable because of these limitations. Thymic epithelial tumors (TETs) are rare neoplastic mediastinal lesions, with a reported incidence of 0.
View Article and Find Full Text PDFSensors (Basel)
January 2025
School of Biomedical Engineering, Tsinghua University, Shuang Qing Road, Beijing 100084, China.
Mastoidectomy is critical in acoustic neuroma surgery, where precise planning of the bone milling area is essential for surgical navigation. The complexity of representing the irregular volumetric area and the presence of high-risk structures (e.g.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Department of Electrical and Software Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada.
The fusion of synthetic aperture radar (SAR) and optical satellite imagery poses significant challenges for ship detection due to the distinct characteristics and noise profiles of each modality. Optical imagery provides high-resolution information but struggles in adverse weather and low-light conditions, reducing its reliability for maritime applications. In contrast, SAR imagery excels in these scenarios but is prone to noise and clutter, complicating vessel detection.
View Article and Find Full Text PDFBMC Ophthalmol
January 2025
Department of Ophthalmology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
Objective: To examine the relationship between retinal vascular geometry and silent brain infarction (SBI) in the Chinese population.
Methods: We conducted a cross-sectional study that retrospectively analyzed the fundus photographs, MRI and other clinical data of 227 SBIs and 227 controls who visited Shanghai Health And Medical Center for physical examination. The retinal vessel fractal dimension (FD), retinal artery fractal dimension (FDa), retinal vein fractal dimension (FDv), central retinal artery diameter in the region from 0.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!