In order to study whether different heart rates achieved at peak exercise by normal subjects and patients with coronary artery disease (CAD) affect the results of analysis of R-wave amplitude changes (delta R), we evaluated delta R at progressively increasing heart rate (HR) steps in 60 normal subjects with negative exercise tests (ET), in 130 patients with CAD, in 88 patients with true positive and 42 with false negative ET, and in 43 patients with no CAD and false positive ET. We found that the sensitivity and specificity of delta R were HR dependent, the former decreasing and the latter increasing with progressively increasing HR steps. Mean values of delta R did not discriminate among the four groups for HRs up to 150 bpm; significant differences were found between normal subjects and CAD patients, both with true positive and false negative stress tests, at HR greater than 150 bpm. False positive patients had mean delta R similar to those found in normal subjects. We hypothesize that quantitative delta R analysis could be useful in ECG diagnosis of false negative and false positive patients at HR greater than 150 bpm.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0002-8703(84)90134-0 | DOI Listing |
J Med Virol
January 2025
State Key Laboratory of Pathogen and Biosecurity, Academy of Military Medical Science, Beijing, China.
Severe fever with thrombocytopenia syndrome (SFTS) is an emerging tick-borne disease with a high fatality rate. The clinical diagnosis criteria mainly rely on white blood cell (WBC) and platelet (PLT), which, however, are of limited usage in identifying atypical SFTS. A multicenter study was performed in two hospitals from 2011 to 2023.
View Article and Find Full Text PDFMagn Reson Med
January 2025
Department of Radiology, University of Missouri, Columbia, Missouri, USA.
Purpose: The aim of the work is to develop a cascaded diffusion-based super-resolution model for low-resolution (LR) MR tagging acquisitions, which is integrated with parallel imaging to achieve highly accelerated MR tagging while enhancing the tag grid quality of low-resolution images.
Methods: We introduced TagGen, a diffusion-based conditional generative model that uses low-resolution MR tagging images as guidance to generate corresponding high-resolution tagging images. The model was developed on 50 patients with long-axis-view, high-resolution tagging acquisitions.
J Cardiothorac Surg
January 2025
Cardiovascular Research Center, Health Policy and Promotion Institute, Imam-Ali Hospital, Kermanshah University of Medical Sciences, Kermanshah, Iran.
Background: The lacking proper regulation of International Normalized Ratio (INR) as the main problem in patients with mechanical valve replacement surgery poses the risk of thrombosis and embolism on the one hand and the risk of bleeding on the other. For this reason, the correct monitoring of INR via the Time in Therapeutic Range (TTR) is needed. The present study aimed to explore the blood coagulation monitoring of patients with mechanical heart valve in Imam Ali Hospital of Kermanshah in 2021.
View Article and Find Full Text PDFBMC Musculoskelet Disord
January 2025
Lecturer of Physical Therapy, Basic Science Department, Faculty of Physical Therapy, Suez University, Suez, Egypt.
Background: pelvis and shoulder are deeply integrated. They are connected by myofascial slings. The pelvic and spinal posture affects the position of the scapula and the activity of its muscles and affects acromio-humeral distance and so that affects shoulder movement.
View Article and Find Full Text PDFBMC Ophthalmol
January 2025
Department of Optometry, School of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Background: The psychometric properties of the Convergence Insufficiency Symptom Survey (CISS) have been previously determined across the younger adult population. This study investigated the psychometric properties of the CISS in presbyopic adults via classical and Rasch analysis.
Methods: A total of 100 presbyopic individuals (40-60 years) were selected with far and near acuity of 20/20 with their habitual spectacles; 50 had convergence insufficiency and 50 had normal binocular vision.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!