AI Article Synopsis

Article Abstract

Argon laser photocoagulation is an effective surgical modality in the management of open-angle glaucoma. Twenty-two eyes with open-angle glaucoma were treated. Approximately 50 burns of 50 micron spot size were applied to the anterior trabeculum over the inferior 180 degrees of the angle. An average pressure drop of 6.1 mmHg was achieved. Complications were minimal, a transient postoperative pressure rise being the most potentially hazardous.

Download full-text PDF

Source

Publication Analysis

Top Keywords

open-angle glaucoma
12
argon laser
8
laser photocoagulation
8
photocoagulation trabecular
4
trabecular meshwork
4
meshwork open-angle
4
glaucoma argon
4
photocoagulation effective
4
effective surgical
4
surgical modality
4

Similar Publications

Purpose: To assess real-world efficacy and safety of standalone travoprost intracameral implant (iDose TR) implantation by a US glaucoma surgeon in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT).

Methods: This non-randomized, retrospective, unmasked, consecutive case series included all cases of standalone iDose TR implantation from a single US glaucoma surgeon since the product's approval by the US Food and Drug Administration (FDA) in December 2023. Patients were pseudophakic, had OAG or OHT, and had undergone prior SLT and/or bimatoprost intracameral implant injection (Durysta).

View Article and Find Full Text PDF

Purpose: To assess the safety and efficacy of a modified suprachoroidal silicone tube (SST) shunt in patients with primary open-angle glaucoma (POAG) and pseudo-exfoliative glaucoma (PXG) in this experimental study.

Methods: In this single-center, retrospective longitudinal data analysis 66 eyes of 59 patients having POAG and PXG were included and treated with modified SST shunt in combination with cataract or as a stand-alone procedure. Pre- and postoperative intraocular pressure (IOP), best corrected visual acuity (BCVA), C/D ratio and ocular adverse events (AEs) were assessed in all participants.

View Article and Find Full Text PDF

Purpose: To develop an artificial intelligence algorithm to automatically identify the anterior segment structures and assess multiple parameters of primary angle closure disease (PACD) in ultrasound biomicroscopy (UBM) images.

Design: Development and validation of an artificial intelligence algorithm for UBM images.

Methods: 2339 UBM images from 592 subjects were collected for algorithm development.

View Article and Find Full Text PDF

Elevation of intraocular pressure (IOP) due to trabecular meshwork (TM) dysfunction, leading to neurodegeneration, is the pathological hallmark of primary open-angle glaucoma (POAG). Impaired axonal transport is an early and critical feature of glaucomatous neurodegeneration. However, a robust mouse model that accurately replicates these human POAG features has been lacking.

View Article and Find Full Text PDF

This case study details a 41-year-old male patient with Freeman-Sheldon syndrome (FSS) who presented with ocular hypertension. The intraocular pressure (IOP) in his right eye progressively increased over time, leading to visual field loss, culminating in a diagnosis of juvenile-onset open-angle glaucoma (JOAG). Despite conventional medical therapies, adequate IOP control was not achieved, necessitating his referral to Nagoya City University Hospital.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!