Cineradiography is the most accurate and rapid method in evaluation of the function of Björk-Shiley prosthetic valves manufactured after late 1975 and which incorporate a tantalum foil hoop into the disc. This helps in demonstration of the disc and in the calculation of the opening angle of the disc. In the present series 8 cases with valve dysfunction have been correctly diagnosed by conventional cineradiography, 7 in the mitral and one in the aortic position. In all 8 cases and also in the group of 300 postoperative cases having no symptoms, the opening angle has been measured by the method described by Venkataraman et coll. in 1980. It is recommended that in accordance with the suggestions of these authors, the opening angle should be established for each patient in the immediate postoperative period in order to provide a basis for possible future examinations.

Download full-text PDF

Source
http://dx.doi.org/10.1177/028418518302400503DOI Listing

Publication Analysis

Top Keywords

opening angle
12
thrombosis björk-shiley
4
björk-shiley valve
4
valve prostheses
4
prostheses evaluation
4
evaluation cineradiography
4
cineradiography cineradiography
4
cineradiography accurate
4
accurate rapid
4
rapid method
4

Similar Publications

In trenchless pipe jacking engineering practice, the formation of high-quality slurry jacket on the outer wall of pipe section is the key to effectively reducing the pipe-soil frictional resistance, improving the construction efficiency, reducing the construction risk and ensuring the construction safety. Herein, the multifunctional experimental apparatus for the pipe-soil frictional resistance testing is improved to ensure the smooth implementation of the subsequent experimental research. The influences of the structural parameters of grouting holes in circular and rectangular pipe sections on the pipe-soil frictional resistance and the states of slurry jackets around the various pipe sections are investigated respectively based on orthogonal experiment.

View Article and Find Full Text PDF

Bottlebrush block polymers, characterized by densely grafted side chains extending from a backbone, have recently garnered significant attention. A particularly attractive feature is the accessibility of ordered morphologies with domain spacings exceeding several hundred nanometers, a capability that is challenging to achieve with linear polymers. These large morphologies make bottlebrush block polymers promising for various applications, such as photonic crystals.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to examine the outcomes following opening-wedge high tibial osteotomy (HTO) focusing on return to sports in a consecutive series of highly active patients who underwent a unilateral osteotomy procedure.

Methods: Sixty-three consecutive patients with preoperative Tegner's activity score of five or more who underwent unilateral HTO for varus osteoarthritic knees were included in this study. The clinical results were evaluated using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the International Knee Documentation Committee (IKDC) Subjective Score.

View Article and Find Full Text PDF

In solid-state nuclear magnetic resonance (ssNMR) spectroscopy, fast magic angle spinning (MAS) is a potent technique that efficiently reduces line broadening and makes it possible to probe structural details of biological systems in high resolution. However, its utilization in studying complex heterogeneous biomaterials such as bone in their native state has been limited. The present study has demonstrated the feasibility of acquiring two-dimensional (2D) H-H correlation spectra for native bone using multiple-quantum/single-quantum correlation experiments (MQ/SQ) at fast MAS (70 kHz).

View Article and Find Full Text PDF
Article Synopsis
  • Knee pain often involves varus deformity and unicompartmental osteoarthritis, where high tibial valgus osteotomy (HTO) has emerged as an effective treatment option to delay joint replacement.
  • A case report highlighted two patients with bilateral knee arthritis who underwent medial opening-wedge high tibial osteotomy using Dr. Saigal's plate, both achieving good range of motion and minimal complications post-surgery.
  • Comprehensive evaluations, including radiological assessments and specific surgical techniques like the Miniaci Method, were employed to ensure successful outcomes, with both patients showing significant improvement after one year.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!