Long-term anchorage of foreign material in vital bone has proven to be the main problem in endoprosthetics. In the authors' opinion, modelling an endoprosthetic anchorage component to the individual anatomic needs is, at present, the best way to transmit stresses harmoniously from the prosthesis to the sensitive bone, in order to utilize functional adaptation, and to guarantee long-term function. The production of a true-to-scale joint model is possible with computer-assisted tomography. This model of the joint or bone canal can be used to construct an individual endoprosthesis prior to surgery. A procedure described.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF00443036DOI Listing

Publication Analysis

Top Keywords

computer-aided manufacture
4
manufacture individual
4
individual endoprostheses
4
endoprostheses preliminary
4
preliminary communication
4
communication long-term
4
long-term anchorage
4
anchorage foreign
4
foreign material
4
material vital
4

Similar Publications

Load-bearing capacity of an experimental dental implant made of Nb-1Zr.

J Mater Sci Mater Med

January 2025

Clinic of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany.

Although implants have undergone a remarkable development over the past decades, modern implants still show complications that make the improvement of materials necessary. The presented study investigates the load-bearing capacity of an experimental dental implant made of a niobium alloy (Nb1Zr) compared to identical implants made of Ti6Al4V using chewing simulation for artificial aging. Eight implants each with an experimental design were manufactured from Nb1Zr and Ti6Al4V.

View Article and Find Full Text PDF

The advancement of information technology and AI has boosted global economic and social development. Robot systems (RS) and computer-aided technology (CAT) are used in various domains, including social production and human existence. Traditional fracture reduction surgery relies on the expertise and surgical skills of surgeons to realign fractures in patients.

View Article and Find Full Text PDF

Despite being a high-resolution separation technique, deterministic lateral displacement (DLD) technology is facing multiple challenges with regard to design, manufacture, and operation of pertinent devices. This work specifically aims at alleviating difficulties associated with design and manufacture of DLD chips. The process of design and production of computer-aided design (CAD) mask layout files that are typically required for computational modeling analysis, optimization, as well as for manufacturing DLD-based micro/nanofluidic chips is complex, time-consuming, and often necessitates a high level of expertise in the field.

View Article and Find Full Text PDF

Purpose: This study aims to evaluate the effects of taper angle and the number of insertion-removal cycles on the retention force of 4 mol% yttria partially stabilized zirconia (4Y-PSZ) double crowns over time.

Materials And Methods: Primary and secondary crowns were fabricated using 4Y-PSZ with taper angles of 2°, 4°, and 6° (n=15). Retention force during crown removal was measured after applying 50-N and 100-N loads.

View Article and Find Full Text PDF

Comparing analog and 3D measurements of vertical dimension in edentulous subjects.

J Dent

January 2025

Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland; School of Dentistry, Federal University of Goiàs, Goiania, Brazil; Department of Reconstructive Dentistry, Division of Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.

Objective: This study aimed to explore the feasibility and reliability of measuring the vertical dimension of occlusion/rest (OVD/RVD) on 3D facial scans of edentulous patients.

Methods: Nineteen edentulous participants rehabilitated with complete removable dental prostheses (CDs) participated in this study. Analog measurements (control) were obtained directly on the face for each participant with the jaws positioned at the rest position (without CDs, RVD) and at central occlusion (OVD), between the facial landmarks: Glabella (G) and Soft Pogonion (SP), Pronasale (PN) and SP, and Subnasale (SN) and SP.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!