The first prototypes of an abdominal phantom have been constructed. The phantom is intended for eventual use in training diagnostic ultrasound personnel and in demonstrating commercial equipment. It is constructed from plastics believed to be stable and approximately tissue-equivalent at room temperature. Abdominal structures are formed from a dispersion of a polystyrene butadiene plastic in mineral oil. Polyvinyl chloride particles are incorporated to provide the desired attenuation coefficients and scattering levels. B-scans of the phantom produced realistic images, although problems associated with scanning technique and somewhat high phantom attenuation were noted. Very useful phantoms should result from relatively simple improvements in construction techniques.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.7863/jum.1983.2.10.455 | DOI Listing |
J Vasc Surg Cases Innov Tech
April 2025
Department of Radiology and Nuclear Medicine, University Teaching and Research Hospital Lucerne, Luzern, Switzerland.
Objective: The aim of this single-center case series is to demonstrate that an ultra-low dose (ULD) can be routinely achieved in the hybrid operating room in standard endovascular aortic repair (EVAR) for infrarenal abdominal aortic aneurysm by adjusting the manufacturer's predefined imaging parameters, hardware configurations and user protocols (including benchmarking).
Methods: The hybrid operating room manufacturer predefined EVAR software setup of the dose exposure control software (OPTIQ, Siemens Healthineers, Forchheim, Germany) at our university medical center was screened for possible improvements regarding radiation dose application. Tests on a water-equivalent as well as polymethyl methacrylate phantom model to assess the impact of technical settings were performed, including comparison of settings for exposure control software, different magnification, collimation configurations and detector distance.
Cureus
December 2024
Department of Diagnostic Imaging and Radiotherapy, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Kuantan Campus, Kuantan, MYS.
In abdominal X-ray examinations, radiosensitive organs such as the gonads within or near the imaging region are at risk of radiation exposure. Minimizing the dose to these organs is crucial to reducing unnecessary radiation. This study utilized optically stimulated luminescence dosimeters (OSLDs) to measure the radiation dose to the male gonads at varying kilovoltage peak (kVp) settings while keeping the milliampere-seconds (mAs) constant across different radiographic projections.
View Article and Find Full Text PDFQuant Imaging Med Surg
January 2025
Department of Imaging Medicine and Nuclear Medicine, Shandong Second Medical University, Weifang, China.
Background: Rapid kilovolt (kV)-switching dual-energy computed tomography (DECT) has been increasingly applied to the measurement of lumbar spine bone mineral density (BMD) in humans and animal models. The objective of this study was to investigate the optimal parameters for the measurement of vertebral BMD. The BMD of the spinal model was measured by means of DECT in combination with different noise index (NI) and preset adaptive statistical iterative reconstruction Veo (ASiR-V) levels.
View Article and Find Full Text PDFPhysiol Meas
January 2025
Electronics, Universidad Favaloro, Solis 453, Buenos Aires, Buenos Aires, 1078, ARGENTINA.
Aortic dilatation is a severe pathology that increases the risk of rupture and its hemodynamics could be accurately assessed by using the 4D flow cardiovascular magnetic resonance (CMR) technique but flow assessment under complex flow patterns require validation. The aim of this work was to develop an in vitro system compatible with CMR to assess the accuracy of volume flow measurements in dilated aortas. Approach.
View Article and Find Full Text PDFJMIR Serious Games
January 2025
Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Background: Ultrasound education is transitioning from in-person training to remote methods using mixed reality (MR) and 5G networks. Previous studies are mainly experimental, lacking randomized controlled trials in direct training scenarios.
Objective: This study aimed to compare an MR-based telesupervised ultrasound education platform on private 5G networks with traditional in-person training for novice doctors.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!