Alveolar hypoxia is a well established cause of regional vasoconstriction such that nonventilated segments are not perfused. The paradoxical situation of retained perfusion of nonventilated lung has seldom been discussed. Three clinical examples are illustrated. In each case coexistent chronic obstructive lung disease may have contributed to this unexpected finding by reducing pulmonary vascular capacity such that blood flow diversion from hypoxic segments was not possible.

Download full-text PDF

Source
http://dx.doi.org/10.2214/ajr.141.1.151DOI Listing

Publication Analysis

Top Keywords

perfusion nonventilated
8
nonventilated lung
8
lung failure
4
failure hypoxic
4
hypoxic vasoconstriction?
4
vasoconstriction? alveolar
4
alveolar hypoxia
4
hypoxia well
4
well established
4
established regional
4

Similar Publications

Objective: To establish an arterial spin labeling (ASL) protocol for rat livers that improves data reliability and reproducibility for perfusion quantification.

Methods: This study used respiratory-gated, single-slice, FAIR-based ASL imaging with multiple inversion times (TI) in rat livers. Quality assurance measures included: (1) introduction of mechanical ventilation to ensure consistent respiratory cycles by controlling the respiratory rate (45 bpm), tidal volume (10 ml/kg), and inspiration: expiration ratio (I:E ratio, 1:2), (2) optimization of the trigger window for consistent trigger points, and (3) use of fit residual map and coefficient of variance as metrics to assess data quality.

View Article and Find Full Text PDF

The effects of thoracic epidural blockade on ventilation-perfusion matching during one-lung ventilation: An exploratory study.

J Clin Anesth

December 2024

Department of Critical Care Medicine, Zhongshan Hospital, Fudan University, Shanghai, China; Shanghai Institute of Infectious Disease and Biosecurity, School of Public Health, Fudan University, Shanghai, China; Shanghai Key Laboratory of Lung Inflammation and Injury, Shanghai, China. Electronic address:

Article Synopsis
  • The study explored the use of electrical impedance tomography (EIT) to evaluate the impact of thoracic epidural blockade (TEB) combined with general anesthesia on lung function during one-lung ventilation (OLV) in patients undergoing thoracic surgery.
  • Thirty patients were randomly assigned to either a control group or a TEB group, where EIT measurements and blood gas analysis were performed to assess pulmonary perfusion distribution and ventilation-perfusion (V/Q) matching at different stages of the procedure.
  • Results indicated that TEB significantly decreased mean arterial pressure and worsened arterial oxygen levels and shunt percentages during OLV, suggesting it adversely affected respiratory function in these patients.
View Article and Find Full Text PDF

Pathophysiological Markers of Acute Respiratory Distress Syndrome Severity Are Correlated With Ventilation-Perfusion Mismatch Measured by Electrical Impedance Tomography.

Crit Care Med

January 2025

Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.

Objectives: Pulmonary ventilation/perfusion (V/Q) mismatch measured by electrical impedance tomography (EIT) is associated with the outcome of patients with the acute respiratory distress syndrome (ARDS), but the underlying pathophysiological mechanisms have not been fully elucidated. The present study aimed to verify the correlation between relevant pathophysiological markers of ARDS severity and V/Q mismatch.

Design: Prospective observational study.

View Article and Find Full Text PDF

Effects of Positive End-expiratory Pressure on Pulmonary Perfusion Distribution and Intrapulmonary Shunt during One-lung Ventilation in Pigs: A Randomized Crossover Study.

Anesthesiology

July 2024

Department of Intensive Care and Resuscitation, Department of Outcomes Research, and Department of Cardiothoracic Anesthesia, Anesthesiology Institute, Cleveland Clinic, Cleveland, Ohio.

Background: During one-lung ventilation (OLV), positive end-expiratory pressure (PEEP) can improve lung aeration but might overdistend lung units and increase intrapulmonary shunt. The authors hypothesized that higher PEEP shifts pulmonary perfusion from the ventilated to the nonventilated lung, resulting in a U-shaped relationship with intrapulmonary shunt during OLV.

Methods: In nine anesthetized female pigs, a thoracotomy was performed and intravenous lipopolysaccharide infused to mimic the inflammatory response of thoracic surgery.

View Article and Find Full Text PDF

Pathophysiological profile of non-ventilated lung injury in healthy female pigs undergoing mechanical ventilation.

Commun Med (Lond)

February 2024

Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.

Background: Lung regions excluded from mechanical insufflation are traditionally assumed to be spared from ventilation-associated lung injury. However, preliminary data showed activation of potential mechanisms of injury within these non-ventilated regions (e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!