The MICs of 10 antimicrobial agents were determined for 1,000 clinical aerobic and facultatively anaerobic gram-negative bacilli by the 6-h AutoMicrobic system Gram-Negative General Susceptibility-Plus Card (GSC+) (Vitek Systems, Inc., Hazelwood, Mo.) and by an 18-h reference agar dilution method. Results obtained by both systems were evaluated for twofold dilution discrepancies and for interpretive category discrepancies. MICs that differed by more than one twofold dilution between the two test systems were considered to be discrepant. The overall twofold dilution agreement of the GSC+ MICs to agar dilution MICs was 94.0%. The agreement for each drug tested ranged from 91.7% (ampicillin and chloramphenicol) to 96.5% (carbenicillin). Interpretive categories were considered in agreement when the susceptibility interpretations obtained by the two systems were both very susceptible, moderately susceptible, or resistant. The overall interpretive category agreement was 80.5%. This agreement increased to 95.8% when all minor errors (moderately susceptible, one system; very susceptible, the other system) that would not affect therapy were omitted. The AutoMicrobic system GSC+ provides rapid and accurate susceptibility test results for clinical aerobic and facultatively anaerobic gram-negative bacilli.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC271399 | PMC |
http://dx.doi.org/10.1128/jcm.20.4.630-635.1984 | DOI Listing |
Asian Pac J Trop Med
November 2013
Laboratory Department, Xijing Hospital, Fourth Military Medical University, Xi'an 710032, China.
Objective: To explore the antibiotic resistance of Brucella melitensis and instruct rational use of antimicrobial agents in clinical treatment of Brucella infection.
Methods: Bacteria were cultured and identified by BACTEC9120 and VITEK II automicrobic system. E-test was used to detect the minimal inhibitory concentration (MIC) of antimicrobial agents in the drug susceptivity experiment.
Exp Ther Med
January 2013
Departments of Infection Control and.
The aim of the present study was to characterize the distribution and antibiotic resistance of pathogens isolated from patients with bloodstream infections (BSIs) in the Hematology and Oncology department of the Affiliated Children's Hospital of Zhejiang University Medical School (Hangzhou, China), between January and December 2010 and to provide early and appropriate support for the clinical administration of antibiotics. Out of 1,500 inpatients, 161 children who were diagnosed with BSI based on the national diagnostic criteria were retrospectively analyzed. Neutropenia was defined as an absolute neutrophil count (ANC) in the peripheral blood of less than 0.
View Article and Find Full Text PDFBioresour Technol
July 2012
The Key Laboratory of Eco-environments in Three Gorges Reservoir Region, Chongqing University, Chongqing 400045, PR China.
A heterotrophic nitrifier, strain NR, was isolated from a membrane bioreactor. Strain NR was identified as Alcaligenes faecalis by Auto-Microbic system and 16S rRNA gene sequence analysis. A.
View Article and Find Full Text PDFMem Inst Oswaldo Cruz
March 2006
Departamento de Microbiología, Escuela Nacional de Ciencias Biológicas, Instituto Politécnico Nacional, Apartado Postal CON 174 CP 06400 México, D. F.
A total of 221 strains of Aeromonas species isolated in Mexico from clinical (161), environmental (40), and food (20) samples were identified using the automated system bioMérieux-Vitek. Antisera for serogroups O1 to 044 were tested using the Shimada and Sakazaki scheme. The K1 antigen was examined using as antiserum the O7:K1C of Escherichia coli.
View Article and Find Full Text PDFObjective: To assess the occurrence frequency of bacterial pathogens at the Surgical Wards, Casualty and Outpatient Department (OP) of major Kuwaiti hospital and to compare their antimicrobial susceptibility patterns.
Methods: The Automicrobic System (bioMerieux-Vitek) with respective ready-to-use cards were used for identification of isolates and their susceptibility testing. Vitek DataTrac software automatically tabulated the occurrence rate of pathogens or their antimicrobial susceptibility percentage--for defined periods of time and specified patient locations.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!