The presence of periprosthetic gas on computerized axial tomography (CT) of the abdomen following abdominal aortic reconstruction has been proposed to be a reliable indicator of prosthetic graft infection, a complication that requires intervention entailing significant mortality and morbidity. To evaluate the reliability of this finding in the early postoperative period, prosthetic grafts in 26 patients undergoing elective aneurysm repair were evaluated with postoperative CT examinations. Serial scans were obtained at mean intervals of 3, 7, and 52 days postoperatively. The presence or absence of periprosthetic air on CT scan was noted, and the results were correlated with aneurysm size as determined by preoperative ultrasound examination of the abdominal aorta or by measurements made during operation. Mean aneurysm size was 6.1 cm (range 4.5 to 10.6 cm). Periprosthetic air was demonstrated in 17 (65%) of the 26 patients studied within 1 week postoperatively. Patients with aneurysms larger than 6.0 cm were more likely to demonstrate periprosthetic air then those with smaller aneurysms (chi 2 = 5.024, p = 0.025). All patients found to have periprosthetic air had spontaneous resolution by late CT scanning obtained a mean of 52 days postoperatively (range 21 to 85 days). One patient died in the early postoperative period and two did not return for late scans. Only one patient demonstrated periprosthetic air as late as the thirty-second postoperative day, and this air had resolved by the seventieth postoperative day.(ABSTRACT TRUNCATED AT 250 WORDS)
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1067/mva.1984.avs0010429 | DOI Listing |
Int Microbiol
January 2025
Department of Orthopedics and Traumatology, Ankara University School of Medicine, Ankara, Turkey.
Purpose: The most frequently used surgical procedures for periprosthetic joint infections (PJIs) are debridement, antibiotics, and implant retention (DAIR), as well as single- or two-stage revision arthroplasty. The choice of surgery is made depending on the full maturation of the biofilm layer. The purpose of this study was to evaluate the biofilm formation and microbial growth using common PJI-causing agents and compare its development on the implant surface.
View Article and Find Full Text PDFJ Clin Med
October 2024
Department of Anatomy, School of Medicine, Faculty of Health Sciences, National and Kapodistrian University of Athens, 15772 Athens, Greece.
: Data regarding fungal PJIs of the shoulder are scarce. The present systematic review aims to identify and evaluate all published shoulder fungal PJIs in an effort to better understand the diagnostic and therapeutic approach to these infections. : A systematic review according to the PRISMA guidelines was conducted, locating all shoulder fungal PJIs.
View Article and Find Full Text PDFJ ISAKOS
December 2024
Sydney Orthopaedic Research Institute, Sydney Australia. Electronic address:
Periprosthetic joint infection (PJI) is a complication that occurs in less than 1% of patients after unicompartmental knee arthroplasty (UKA). Though infrequent, it may potentially lead to revision while placing a significant financial burden on the healthcare system. Preoperative, intra-operative, and postoperative strategies should be implemented to minimize the risk of PJI.
View Article and Find Full Text PDFJ Cardiovasc Echogr
June 2024
Department of Cardiology, Hospital Center of Trás-os-Montes e Alto Douro, Vila Real, Portugal.
A 54-year-old patient with a medical history of hypertension, dyslipidemia, and diabetes underwent mitral valve replacement surgery with a biologic valve. During a chest computed tomography scan for breast neoplasia staging, a reduced luminal filling in the left atrium (3.6 cm) was unexpectedly found, prompting further cardiac evaluation.
View Article and Find Full Text PDFJ Biol Chem
June 2024
Department of Orthopedics, Nanjing Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China; Department of Orthopedics, Air Force Hospital of Eastern Theater, Anhui Medical University, Nanjing, China. Electronic address:
Periprosthetic osteolysis and subsequent aseptic loosening are the primary causes of failure following total joint arthroplasty. Wear particle-induced osteogenic impairment is recognized as an important contributing factor in the development of osteolysis, with endoplasmic reticulum (ER) stress emerging as a pivotal underlying mechanism. Hence, searching for potential therapeutic targets and agents capable of modulating ER stress in osteoblasts is crucial for preventing aseptic loosening.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!