Percutaneous vertebral trephine biopsy is a valuable investigation. A new type of trephine needle for vertebral biopsy is described in this paper. This trephine needle is introduced on the thin needle used for local anesthesia, following a procedure similar to vascular catheterism. Thus, the same puncture is used for local anesthesia and bone biopsy. Therefore, local anesthesia is more effective and the biopsy procedure is much safer, particularly at the thoracic level where vital organs are very close to the spine. A very practical handle design for advancing the trephine needle on the guide wire makes the biopsy procedure easy and precise. This trephine needle enhance indications of this potentially valuable procedure.
Download full-text PDF |
Source |
---|
Int J Surg Case Rep
October 2024
Department of Otolaryngology, Head and Neck Surgery, Ibn Rochd University Hospital, Faculty of Medicine and Pharmacy, Hassan II University, Casablanca, Morocco.
Micromachines (Basel)
June 2024
Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD 21218, USA.
Partial-thickness corneal transplants using a deep anterior lamellar keratoplasty (DALK) approach has demonstrated better patient outcomes than a full-thickness cornea transplant. However, despite better clinical outcomes from the DALK procedure, adoption of the technique has been limited because the accurate insertion of the needle into the deep stroma remains technically challenging. In this work, we present a novel hands-free eye mountable robot for automatic needle placement in the cornea, AutoDALK, that has the potential to simplify this critical step in the DALK procedure.
View Article and Find Full Text PDFObjective: To evaluate the feasibility of transthoracic CT-guided core biopsy of high pulmonary neoplasms using coaxial transport system in a day hospital; to analyze the effectiveness, nature and incidence of complications, as well as pain indicators in both groups.
Material And Methods: Transthoracic CT-guided core biopsy of high pulmonary neoplasms using coaxial transport system in a day hospital was performed in 184 patients for histological verification between March 2017 and December 2022.
Results: This method of transthoracic biopsies significantly (<0.
Bucket-handle meniscus tears alter knee biomechanics and significantly elevate the risk of osteoarthritis when the tissue is not preserved. Consequentially, meniscus repair is preferred whenever possible to optimize load distribution and knee stability, with the overall goal of joint preservation. Bucket-handle meniscus tears have a higher rate of repair failure compared with many other tear patterns, and both the inside-out (IO) and all-inside (AI) techniques are acceptable options, each with distinct advantages and disadvantages.
View Article and Find Full Text PDFJ Foot Ankle Surg
February 2024
Internal Medicine - Infectious Disease, University of Iowa, Iowa City, IA.
Standardized methods for osteomyelitis (OM) diagnosis of the lower extremity have proven to be difficult. Preoperative probability of foot osteomyelitis necessitates a combination of clinical, laboratory, imaging evidence (i.e.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!