Download full-text PDF

Source

Publication Analysis

Top Keywords

electrostimulation-induced changes
4
changes enzyme
4
enzyme activity
4
activity pattern
4
pattern dystrophic
4
dystrophic mouse
4
mouse muscles
4
electrostimulation-induced
1
enzyme
1
activity
1

Similar Publications

Significance: Neuromodulation devices are rapidly evolving for the treatment of neurological diseases and conditions. Injury from implantation or long-term use without obvious functional losses is often only detectable through terminal histology. New technologies are needed that assess the peripheral nervous system (PNS) under normal and diseased or injured conditions.

View Article and Find Full Text PDF

High-volume intermittent maximal intensity isometric exercise caused great stress, although central motor fatigue did not occur.

Biol Sport

September 2021

Department of Rehabilitation, Physical and Sports Medicine, Faculty of Medicine, Vilnius University, M. K. Čiurlionio str. 21/27, LT-03101, Vilnius, Lithuania.

To establish whether very high-volume, high-intensity isometric exercise causes stress to the body and how it affects peripheral and central fatigue. Nineteen physically active healthy male subjects (21.2 ± 1.

View Article and Find Full Text PDF

Objectives: To investigate the effect of 4-chloro-7-trifluoromethyl-10H-benzo[4,5]furo[3,2-b]indole-1-carboxylic acid, a new benzofuroindole derivative, on the intraurethral pressure in a rat model of benign prostatic hyperplasia.

Methods: Benign prostatic hyperplasia was induced by testosterone and 17β-estradiol, which were administered intramuscularly once a day for 12 weeks. The effects of 4-chloro-7-trifluoromethyl-10H-benzo[4,5]furo[3,2-b]indole-1-carboxylic acid and tamsulosin on the intraurethral pressure induced by the electrostimulation of hypogastric nerves after a single intravenous injection of 4-chloro-7-trifluoromethyl-10H-benzo[4,5]furo[3,2-b]indole-1-carboxylic acid (10 mg/kg) or tamsulosin (10 μg/kg) were evaluated in a benign prostatic hyperplasia model.

View Article and Find Full Text PDF

Peripheral and central fatigue after muscle-damaging exercise is muscle length dependent and inversely related.

J Electromyogr Kinesiol

August 2010

Laboratory of Human Motorics, Department of Applied Physiology and Physiotherapy of the Lithuanian Academy of Physical Education, Kaunas, Lithuania.

Healthy untrained men performed 10 series of 12 knee eccentric extension repetitions (EE) at 160 degrees /s. The maximal voluntary isometric contraction force of the quadriceps muscle, the maximal rate of electrically induced torque development (RTD) and relaxation (RTR), isokinetic concentric torque at 30 degrees /s, the electrostimulation-induced torque at 20 and 100Hz frequencies were established before and after EE at shorter and longer muscle lengths. Besides, voluntary activation (VA) index and central activation ratio (CAR) were tested.

View Article and Find Full Text PDF

Beta+-sensitive probes are useful tools for the measurement of radiotracer kinetics in small animals. They allow the cost-effective development of new PET tracers and offer the possibility to investigate a variety of cerebral processes. The study's main aim was the in vivo evaluation of a probe system for cerebral surface acquisitions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!