Eight patients with acute respiratory failure (ARF) due to diffuse and rather uniform lung disease were intubated with a double-lumen bronchial tube and ventilated in the lateral decubital position by two synchronized ventilators. Ventilation of each lung was individually adjusted to match the expected regional blood flow (differential ventilation). When ventilation with equal volumes (i.e. 50% of tidal volume to each lung) was performed, a 19% reduction of venous admixture (P less than 0.001) and a 22% increment in arterial oxygen tension (P less than 0.001) were seen. Comcomitantly, the cardiac output increased by 17% (P less than 0.001), to which a reduced pulmonary vascular resistance may have contributed. The net result was a 14% increment of the oxygen availability (P less than 0.001). An attempt to go further, giving 2/3 of the tidal ventilation to the dependent lung, was made on six of the patients. However, this ventilatory pattern did not further improve the gas exchange and also had detrimental effects on the haemodynamics. It is concluded that differential ventilation with equal tidal volumes in the lateral position can substantially improve gas exchange and central haemodynamics in patients with ARF due to diffuse lung disease.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1399-6576.1983.tb01950.xDOI Listing

Publication Analysis

Top Keywords

differential ventilation
12
lung disease
12
gas exchange
12
exchange central
8
central haemodynamics
8
haemodynamics patients
8
arf diffuse
8
ventilation equal
8
improve gas
8
lung
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!