A simple low-cost digital film-analysis system using videodensitometry was developed to quantitate autoradiograms. It is based on a TV-film analysis system coupled to a minicomputer. Digital sampling of transmitted light intensities through the autoradiogram is performed with 8-bit gray levels according to the selected array size (128 X 128 to 1024 X 1024). The performance characteristics of the system provide sufficient stability, uniformity, linearity, and intensity response for use in quantitative analysis. Digital images of the autoradiograms are converted to radioactivity content, pixel by pixel, using step-wedge standards. This type of low-cost system can be installed on conventional mini-computers commonly used in modern nuclear medical facilities. Quantitative digital autoradiography can play an important role, with applications stretching from dosimetry calculations of radiopharmaceuticals to metabolic studies in conjunction with positron-emission tomography.

Download full-text PDF

Source

Publication Analysis

Top Keywords

digital film-analysis
8
film-analysis system
8
system videodensitometry
8
digital
5
system
5
quantitative autoradiography
4
autoradiography radiopharmaceuticals
4
radiopharmaceuticals digital
4
videodensitometry concise
4
concise communication
4

Similar Publications

Optimized scoring of end-to-end dosimetry audits for passive motion management - A simulation study using the IROC thorax phantom.

Phys Med

May 2024

Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria 3000, Australia; School of Science, RMIT University, Melbourne, Victoria 3000, Australia.

Dosimetry audits for passive motion management require dynamically-acquired measurements in a moving phantom to be compared to statically calculated planned doses. This study aimed to characterise the relationship between planning and delivery errors, and the measured dose in the Imaging and Radiation Oncology Core (IROC) thorax phantom, to assess different audit scoring approaches. Treatment plans were created using a 4DCT scan of the IROC phantom, equipped with film and thermoluminescent dosimeters (TLDs).

View Article and Find Full Text PDF

Aim: The aim of this study was to investigate the suitability of three radiochromic film analysis software for stereotactic radiotherapy patient-specific quality assurance (PSQA): FilmQA Pro v5.0, SNC Patient v6.2, and eFilmQA v5.

View Article and Find Full Text PDF

Radiochromic films are useful as dosimeters in high-precision radiotherapy owing to their high spatial resolution. However, when a particle beam is measured using a radiochromic film, the dose cannot be estimated accurately because the film darkness varies with variations in linear energy transfer (LET). This paper proposes a novel method for estimating the LET and the dose based on the film darkness.

View Article and Find Full Text PDF

Purpose: Our purpose was to demonstrate the use of novel planning techniques in producing high-quality stereotactic radiosurgery (SRS) plans using a standard 5 mm multileaf collimator (MLC) and multiple isocenters delivered clinically at a local institution.

Methods And Materials: Novel planning techniques consisted of offset isocenter, variable asymmetrical jaws, and Digital Imagine and Communications in Medicine (DICOM) edits to reduce leaf tip transmission, all with the aim of maximizing dose conformity. A local institution clinical cohort was planned (1-4 targets), and plan conformity metrics common to SRS were compared against conformity metrics from selected previous publications comparing Gamma Knife to linear accelerator SRS using high-definition MLC (2.

View Article and Find Full Text PDF

IMRT national audit in Portugal.

Phys Med

September 2019

Dosimetry and Medical Radiation Physics Section, International Atomic Energy Agency, Vienna, Austria.

Purpose: The IAEA newly developed "end-to-end" audit methodology for on-site verification of IMRT dose delivery has been carried out in Portugal in 2018. The main goal was to evaluate the physical aspects of the head and neck (H&N) cancer IMRT treatments. This paper presents the national results.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!