Detection and evaluation of functionally significant carotid occlusive disease are effectively achieved by noninvasive pressure and/or volume measurements from the eye. Ocular arterial blood pressure is measured by applying either direct compression or suction to evaluate intraocular pressure to the point of arterial collapse. Carotid blood flow is evaluated as it affects ocular volume waveforms, which result from the difference between pulsatile arterial flow and relatively constant venous flow. The relationship between noninvasive measurements from the eyes and carotid blood flow can be predicted using simple models of the cervical-cerebral circulatory system. Proper models verify clinically observed correlations between pressure and volume measurements from the eye and the underlying carotid occlusive disease. Electrical analog circuits provide a method for varying model parameters to simulate abnormalities, producing waveforms with good similarity to waveforms recorded from patients with known vascular or ophthalmic pathology. Further model refinements can be contributed by interested investigators. By using the improved models the strengths and weaknesses of current tests and techniques can then be better defined. Techniques that have been widely used for screening and evaluating potential stroke patients can thereby be modified to give improved functional analysis of these patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/BF02410292 | DOI Listing |
J Biol Eng
January 2025
AVT - Biochemical Engineering, RWTH Aachen University, Forckenbeckstr. 51, D-52074, Aachen, Germany.
Background: Shake flasks are essential tools in biotechnological development due to their cost efficiency and ease of use. However, a significant challenge is the miniaturization of process analytical tools to maximize information output from each cultivation. This study aimed to develop a respiration activity online measurement system via off-gas analysis, named "Transfer rate Online Measurement" (TOM), for determining the oxygen transfer rate (OTR), carbon dioxide transfer rate (CTR), and the respiration quotient (RQ) in surface-aerated bioreactors, primarily targeting shake flasks.
View Article and Find Full Text PDFBMC Pulm Med
January 2025
State Key Laboratory of Respiratory Disease & National Clinical Research Center for Respiratory Disease & National Center for Respiratory Medicine & Guangzhou Institute of Respiratory Health, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, China.
Background: Studies on consistency among spirometry, impulse oscillometry (IOS), and histology for detecting small airway dysfunction (SAD) remain scarce. Considering invasiveness of lung histopathology, we aimed to compare spirometry and IOS with chest computed tomography (CT) for SAD detection, and evaluate clinical characteristics of subjects with SAD assessed by these three techniques.
Methods: We collected baseline data from the Early COPD (ECOPD) study.
BMC Cardiovasc Disord
January 2025
Graduate School of Public Health, St Luke's International University, Tokyo, Japan.
Background: Recent studies revealed an association between small kidney volume and progression of kidney dysfunction in particular settings such as kidney transplantation and transcatheter aortic valve implantation. We hypothesized that kidney volume was associated with the incidence of kidney-related adverse outcomes such as worsening renal function (WRF) in patients with acute heart failure (AHF).
Methods: This study was a single-center retrospective cohort study.
J Gen Intern Med
January 2025
Icahn School of Medicine at Mount Sinai, Institute for Health Equity Research, New York, USA.
Background: Over 60 million patients in the USA have limited English proficiency (LEP) and experience barriers in care. Still, there exists no standardized method of monitoring the utilization of language interpreting services (LIS).
Objective: To introduce a methodological approach to systematically monitor utilization of LIS for LEP patients.
EMBO J
January 2025
Department of Biochemistry, University of Utah School of Medicine, Salt Lake City, UT, 84112-5650, USA.
Na-K-Cl cotransporters functions as an anion importers, regulating trans-epithelial chloride secretion, cell volume, and renal salt reabsorption. Loop diuretics, including furosemide, bumetanide, and torsemide, antagonize both NKCC1 and NKCC2, and are first-line medicines for the treatment of edema and hypertension. NKCC1 activation by the molecular crowding sensing WNK kinases is critical if cells are to combat shrinkage during hypertonic stress; however, how phosphorylation accelerates NKCC1 ion transport remains unclear.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!