We developed new sensitive direct radioimmunoassay for human plasma renin. Renin was purified from Haas' preparation utilizing a pepstatin-C6-Sepharose affinity chromatography. Antiserum, prepared by immunizing rabbits with the purified renin, was used for the direct radioimmunoassay at a final dilution of 1:30,000. The antibody was specific for human renal and plasma renin, but did not cross-react with cathepsin D, trypsin, or renins of mouse, dog, and rat. Radioimmunoassay was performed by the double antibody technique using the delayed tracer addition method. In this method, a standard curve was obtained over a range from 0.2 to 8.0 ng/ml. The values from our assay correlated well with total renin activity measured as the generation rate of angiotensin I after trypsin activation (r = 0.78, p less than 0.01), but correlated weakly with active renin activity. This finding disclosed that both active and inactive renin were detected by this method. In normal participants, plasma renin concentration determined by direct radioimmunoassay was increased by standing and furosemide injection. The plasma renin concentration determined by direct radioimmunoassay of patients with essential hypertension (0.7 to 1.7 ng/ml) was not significantly different from values in normal controls (0.8 to 1.9 ng/ml). The values were higher in patients with renovascular hypertension (1.6 to 2.7 ng/ml), malignant hypertension (2.8 to 3.4 ng/ml) and Bartter's syndrome (1.8 to 2.5 ng/ml), but lower in patients with primary aldosteronism (0.4 to 0.8 ng/ml) than in normal controls. This newly developed radioimmunoassay for human renin was sensitive enough to estimate the levels of renin in plasma of patients with low renin hypertension. It provides a new tool for the understanding of the renin-angiotensin system under various clinical conditions.

Download full-text PDF

Source

Publication Analysis

Top Keywords

direct radioimmunoassay
20
plasma renin
20
renin
13
radioimmunoassay human
12
ng/ml values
12
hypertension ng/ml
12
sensitive direct
8
human plasma
8
renin activity
8
renin concentration
8

Similar Publications

Introduction: TSH-receptor antibodies (TRAb) directed against the TSH receptor (TSH-R) induce hyperthyroidism in patients with Graves' disease (GD). TRAb detected by previous radioimmunoassay only reflects the presence of autoantibodies, but not the function of such antibodies. Thyroid stimulating immunoglobulins (TSI) is a relatively new method for assessing TSH-receptor antibodies function.

View Article and Find Full Text PDF

Relationship between serum vitamin D concentration and parameters of gonadal function in infertile male patients.

Curr Urol

September 2024

Area of Clinical Biochemistry, Facultad de CienciasBioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Rosario, Argentina.

Background: Vitamin D (vitD) deficiency could affect male reproductive function. Our objective was to investigate the relationship between serum vitD concentrations and hormonal and seminal parameters in infertile patients and to compare the results with those in healthy controls.

Materials And Methods: Infertile patients (n 29) and normozoospermic healthy donors (n 27) were recruited for the study.

View Article and Find Full Text PDF
Article Synopsis
  • Primary aldosteronism (PA) is a leading cause of high blood pressure, and the study aimed to assess the effectiveness of a new testing method (ADRR) for diagnosing PA compared to the traditional method (ARR).
  • The research involved 1110 patients, discovering that 90 were diagnosed with PA, and found a strong correlation in aldosterone measurements between the two tests.
  • The ADRR method proved to be accurate, achieving a sensitivity of 91% and specificity of 85%, making it a reliable option for diagnosing PA alongside the established RIA method.
View Article and Find Full Text PDF

The prostate-specific antigen (PSA) test is considered an important way for preoperative diagnosis and accurate screening of prostate cancer. Current antigen detection methods, including radioimmunoassay, enzyme-linked immunosorbent assay and microfluidic electrochemical detection, feature expensive equipment, long testing time and poor stability. Here, we propose a portable biosensor composed of electrolyte-gated amorphous indium gallium zinc oxide (a-IGZO) transistors with an extended gate, which can achieve real-time, instant PSA detection at a low operating voltage (<2 V) owing to the liquid-free ionic conductive elastomer (ICE) serving as the gate dielectric.

View Article and Find Full Text PDF

Background: A person's sense of coherence (SoC) is likely to affect coping when exposed to a life changing event like the COVID -19 pandemic, which impacted the older population especially hard, an age group that already suffers from a lot of mental illness. Thus, the aim of this study was to investigate the associations between SoC and mental health in older adults using both screening scales and hair cortisol concentrations (HCC).

Method: A cross-sectional design studying a cohort of 70-80 years old, N = 260, set in Swedish primary care during the pandemic years 2021-2022.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?