A temporary left ventricular assist system utilizing an improved left atrial catheter and centrifugal pump was developed and tried in 22 anesthetized sheep to test the hypothesis that prostacyclin (PGI2) and ionically bound heparin-coated surfaces could prevent thrombosis in this perfusion system without inhibiting soluble, circulating coagulation factors. Sheep were perfused at 53.6 ml/kg/min (standard error, 1.5) from left atrium to aorta for two hours. The pump maintained flow at left atrial pressures of 3 to 4 mm Hg. As expected, systemic heparin inhibited coagulation, mildly activated platelets, and prevented thrombosis in uncoated perfusion circuits and wounds. Infusion of PGI2 (30 ng/kg)min) without systemic heparin or heparin-bonded extracorporeal surfaces prevented platelet activation and did not alter coagulation measurements; however, bleeding times increased and thrombi formed in every circuit. When heparin was ionically bound to all extracorporeal surfaces, infusion of PGI2 completely prevented thrombosis within the circuit, inhibited platelet activation, and did not alter coagulation measurements. Blood spontaneously clotted in three of six thoracotomy wounds during perfusion. When PGI2 infusion was stopped, heparin-coated surfaces alone failed to prevent thrombosis within the system in 3 of 5 animals. The combination of PGI2 infusion and heparin-coated extracorporeal surfaces prevents thrombosis within the perfusion circuit without inhibiting soluble coagulation factors. This method, using the assist system, overcomes many of the implementation and bleeding problems associated with other temporary left ventricular assist devices.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0003-4975(10)60424-9DOI Listing

Publication Analysis

Top Keywords

left ventricular
12
extracorporeal surfaces
12
centrifugal pump
8
temporary left
8
ventricular assist
8
assist system
8
left atrial
8
ionically bound
8
heparin-coated surfaces
8
prevent thrombosis
8

Similar Publications

In 2017, Kidney Disease: Improving Global Outcomes (KDIGO) published a Clinical Practice Guideline Update for the Diagnosis, Evaluation, Prevention, and Treatment of Chronic Kidney Disease-Mineral and Bone Disorder (CKD-MBD). Since then, new lines of evidence have been published related to evaluating disordered mineral metabolism and bone quality and turnover, identifying and inhibiting vascular calcification, targeting vitamin D levels, and regulating parathyroid hormone. For an in-depth consideration of the new insights, in October 2023, KDIGO held a Controversies Conference on CKD-MBD: Progress and Knowledge Gaps Toward Personalizing Care.

View Article and Find Full Text PDF

Background: Atrial fibrillation (AF) is the most prevalent arrhythmia encountered in clinical practice. Triglyceride glucose index (Tyg), a convenient evaluation variable for insulin resistance, has shown associations with adverse cardiovascular outcomes. However, studies on the Tyg index's predictive value for adverse prognosis in patients with AF without diabetes are lacking.

View Article and Find Full Text PDF

This study investigated the correlation between quantitative echocardiographic characteristics within 3 days of birth and necrotizing enterocolitis (NEC) and its severity in preterm infants. A retrospective study was conducted on 168 preterm infants with a gestational age of < 34 weeks. Patients were categorized into NEC and non-NEC groups.

View Article and Find Full Text PDF

Background: The benefit of mechanical circulatory support (MCS) with Impella (Abiomed, Inc, Danvers, MA) for patients undergoing non-emergent, high-risk percutaneous coronary intervention (HR-PCI) is unclear and currently the subject of a large randomized clinical trial (RCT), PROTECT IV. While contemporary registry data from PROTECT III demonstrated improvement of outcomes with Impella when compared with historical data (PROTECT II), there is lack of direct comparison to the HR-PCI cohort that did not receive Impella support.

Methods: We retrospectively identified patients from our institution meeting PROTECT III inclusion criteria (left ventricular ejection fraction [LVEF] <35% with unprotected left main or last remaining vessel or LVEF <30% undergoing multivessel PCI), and compared this group (NonIMP) to the published outcomes data from the PROTECT III registry (IMP).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!