Pacing Clin Electrophysiol
Published: January 1982
Whereas myopotential inhibition of QRS-inhibited (VVI) pacemakers is well known, its occurrence in patients with AV sequential (DVI) pacemakers has not been reported. The present communication deals with spontaneous and induced myopotential inhibition of a multiprogrammable Intermedics unipolar AV sequential (DVI) pacemaker. The bedside maneuvers that were performed in the patient exposed the problem, therefore serving to establish the diagnosis. Although external adjustment of the sensitivity was the simple, non-invasive solution in this case, more studies are required to determine the success rate of this approach as well as the incidence and clinical significance of myopotential inhibition of unipolar DVI pacemakers.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1540-8159.1982.tb02186.x | DOI Listing |
J Interv Card Electrophysiol
November 2023
Boston Scientific, Milan, Italy.
Background: The subcutaneous implantable cardioverter defibrillator (S-ICD) and leadless pacemaker (LP) are alternative options for patients at high risk of infection requiring ICD and pacing therapy. In this analysis, we described the simultaneous implantation of S-ICD and LP in patients with high infectious risk.
Methods: The study cohort comprised patients referred to our institution for ICD implantation due to high-risk factors of infection.
Pacing Clin Electrophysiol
February 2020
Department of Cardiology, Inselspital, Bern University Hospital and the University of Bern, Bern, Switzerland.
Introduction: Diaphragmatic myopotential oversensing (dMPO) by implantable cardioverter defibrillators (ICDs) is thought to be a rare condition that can be misdiagnosed as lead failure and lead to unnecessary lead replacement. We observed several cases of dMPO in patients with Sorin/LivaNova ICDs (MicroPort Sci.).
View Article and Find Full Text PDFEuropace
December 2017
Department of Cardiovascular Biology and Medicine, Niigata University Graduate School of Medical and Dental Sciences, 1-754 Asahimachidori, 951-8510 Niigata, Japan.
Pacing Clin Electrophysiol
July 2016
Hôpital Cardiologique du Haut-Lévêque, CHU Bordeaux, Université Bordeaux, IHU LIRYC, Bordeaux, France.
Diaphragmatic myopotential oversensing (DMO) causes inhibition of pacing and inappropriate detection of ventricular fibrillation in implantable cardioverter defibrillators (ICDs). It occurs almost exclusively with integrated bipolar leads and is extremely rare with dedicated bipolar leads. If DMO cannot be corrected by reducing programmed sensitivity, ventricular lead revision is often required.
View Article and Find Full Text PDFAnn Cardiol Angeiol (Paris)
November 2013
Unité de rythmologie, GHI Le Raincy-Montfermeil, 10, rue du Général-Leclerc, 93370 Montfermeil, France. Electronic address:
In this article, we describe a case of ventricular asystole in a patient implanted with a cardiac pacemaker. The patient had a device replacement. The new pacemaker has been connected to old unipolar leads.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!