Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0002-9610(69)90158-5 | DOI Listing |
Cureus
December 2024
Department of Cardiology, Geetanjali Medical College and Hospital, Udaipur, IND.
Background Carotid artery stenting is a well-established alternative treatment to carotid endarterectomy for carotid artery stenosis for preventing stroke. This study assessed the procedural and clinical outcomes in patients undergoing carotid artery stenting in a tertiary care center in India. Methods A total of 39 patients underwent carotid artery stenting from January 2022 to December 2023, with different embolic protection devices and carotid stents.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
December 2024
The Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, Minnesota, USA.
Introduction: Currently, there are two approved single chamber leadless pacemakers (LP) in the United States (US), Micra VR™; approved since 2016 and AVEIR VR™; approved in 2022. A potential complication of LPs is dislodgement and/or embolization (D/E) during or after implant. According to the IDE trials, there appears to be a significant difference in D/E rates between the two LPs that have different fixation mechanisms; Micra uses nitinol tines, while AVEIR uses an active screw helix.
View Article and Find Full Text PDFJACC Basic Transl Sci
June 2024
CVPath Institute, Gaithersburg, Maryland, USA.
We evaluated a novel dual active pharmaceutical ingredient (API) drug-coated balloon (DCB), which consists of a coating of nanoparticles encapsulating low-dose paclitaxel (PTX) in combination with sirolimus in a synergistic ratio. Compared to the PTX DCB, the dual API DCB demonstrated similar inhibition of cell proliferation in vitro but at a significantly lower total drug dose (over 13 times lower than sirolimus nanoparticles). Animal experiments demonstrated that the dual API DCB is more effective in inhibiting intimal cell proliferation with insignificant downstream embolic effects and myocardial damage compared to the PTX DCB.
View Article and Find Full Text PDFJ Med Case Rep
May 2024
Darnall Medical Library, Walter Reed National Military Medical Center, Bethesda, MD, 20814, USA.
Background: Nexplanon implants are a common hormonal contraceptive modality. Though rare, these devices can embolize into the injured wall of the basilic vein, through the right heart, and finally wedge itself into a pulmonary artery. With adherence to the arterial wall over time, it becomes less amenable to endovascular retrieval.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!