A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurement of visual resolution at high luminance levels in patients with possible demyelinating disease. | LitMetric

An interferometric acuity device (Takata) has been used to study visual resolution in individuals with possible demyelinating disease. The instrument employed provides a large field with a continuous range of grid or fringe frequencies and a relatively intense (10(5) mean photopic trolands) stimulus. After a brief period of time with eyes closed, resolution thresholds of patient are repeatedly determined during a five minute period. In all individuals suspected of having a demyelinating disease tested to date, a fall off in resolution capability has been found in time when using this intense stimulus display. This occurs whether eye signs have been present, are present or have not yet been observed. Normal observers do not exhibit comparable decrements. The fall off in resolution capability may or may not occur at lower stimulus levels, and is often not revealed when testing routine Snellen acuity. Outer and inner retinal pathology (division based on vascular support) do not cause a comparable fall off in resolution in time. The interferometric acuity test is a non-invasive, easily applied test.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF00154196DOI Listing

Publication Analysis

Top Keywords

demyelinating disease
12
fall resolution
12
visual resolution
8
interferometric acuity
8
resolution capability
8
resolution
6
measurement visual
4
resolution high
4
high luminance
4
luminance levels
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!