Segments of small mesenteric arteries(approximately 150 micrometer lumen diameter) and of corresponding veins were taken from 5-month-old spontaneously hypertensive rats(SHR) AND FROM AGE MATCHED Wistar Kyoto (WKY) controls. The segments were mounted on a myograph which enabled their mechanical and morphological parameters to be investigated simultaneously. Compared with the WKY arteries the lumen diameter of the SHR arteries was smaller while the media thickness and active wall tension response were greater. On the other hand there were no differences between the corresponding veins from SHR and WKY animals although, compared with the arteries, the veins had a greater lumen diameter, a smaller media thickness and a smaller tension response. The findings suggest that the morphological and mechanical differences seen in arteries from SHR are not found on the venous side.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1748-1716.1979.tb06480.xDOI Listing

Publication Analysis

Top Keywords

lumen diameter
12
morphological mechanical
8
small mesenteric
8
arteries veins
8
spontaneously hypertensive
8
corresponding veins
8
smaller media
8
media thickness
8
tension response
8
arteries
5

Similar Publications

Current Trends and Perspectives of Pressure Wire-Based Coronary Artery Bypass Grafting.

J Cardiovasc Dev Dis

January 2025

Department of Cardiovascular Surgery, Fujita Health University School of Medicine, 1-98 Dengakugakubo, Kutsukake, Toyoake 470-1192, Aichi, Japan.

Fractional flow reserve (FFR) has been well validated as a modality for evaluating myocardial ischemia, demonstrating the superiority of FFR-guided percutaneous coronary intervention (PCI) over conventional angiography-guided PCI. As a result, the strategy for coronary artery bypass grafting (CABG) is shifting toward FFR guidance. However, the advantage of FFR-guided CABG over angiography-guided CABG remains unclear.

View Article and Find Full Text PDF

Adult patients with central airway tumors commonly present with dyspnea on exertion. These patients may remain asymptomatic until more than half of the airway diameter is obliterated. Anesthesia for debulking a central airway tumor is challenging.

View Article and Find Full Text PDF

Comparison of outcomes with and without intrastent placement during PMS surgery.

Sci Rep

January 2025

Department of Ophthalmology and Visual Science, Kochi Medical School, Kochi University, Kohasu, Oko-cho, Nankoku City, 783-8505, Kochi, Japan.

To assess the efficacy of using a nylon suture as a stent in the PreserFlo MicroShunt (PMS) lumen to prevent postoperative hypotony, 59 eyes that underwent PMS implantation with follow-up for > 6 months were analyzed. Patients were divided into no intrastenting (NST) and intrastenting (ST) groups, with the ST group subdivided into 9 - 0 nylon suture fully placed (9 F), 9 - 0 nylon suture placement in only half of the lumen (9 H), 10 - 0 nylon suture fully placed (10 F), and 10 - 0 nylon suture placement in only half of the lumen (10 H). The distribution was as follows: 23 eyes in the NST group, 10 in the 9 F group, 9 in the 9 H group, 11 in the 10 F group, and 6 in the 10 H group.

View Article and Find Full Text PDF

Evaluation of in-stent restenosis after carotid artery stenting with superb microvascular imaging: initial findings.

Acta Radiol

January 2025

Department of Radiology, Interventional Radiology, Sağlık Bilimleri Üniversitesi Ankara Dışkapı Yıldırım Beyazıt Eğitim ve Araştırma Hastanesi, Ankara, Türkiye.

Background: Carotid artery stenting (CAS) is an interventional management in preventing ischemic stroke caused by carotid artery stenosis. After the treatment with CAS, in-stent restenosis caused by neointimal hyperplasia may develop.

Purpose: This study aims to obtain a better determination of neointimal hyperplasia using superb microvascular imaging (SMI), which provides a high-quality visualization of the endoluminal lesions, and to compare these results with B-mode and Doppler ultrasound (US).

View Article and Find Full Text PDF

Introduction: In the past decade, flow diverters (FDs) have increasingly been used to treat cerebral aneurysms with unfavorable morphology in which other endovascular techniques fall short of being as effective. In-stent stenosis (ISS) is one of the most puzzling and frequent risks of flow diversion therapy observed on follow-ups. This complication, although mostly placid in its clinical course, can have dire consequences if patients become symptomatic.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!