Download full-text PDF |
Source |
---|
Diagnostics (Basel)
June 2024
Cardiology Research Institute, Tomsk National Research Medical Center, Russian Academy of Sciences, 634012 Tomsk, Russia.
(1) Background: An online survey-based observational cross-sectional study aimed at elucidating the experience and attitudes of an unstructured population regarding diagnostic imaging. (2) Methods: Invitations to participate were distributed using mixed-mode design to deidentified residents aged 18 years and older. Main outcome measures included morbidity structure and incidence of diagnostic imaging administrations.
View Article and Find Full Text PDFJ Endovasc Ther
February 2024
Service de Chirurgie Vasculaire, l'institut du thorax, CHU Nantes, Nantes, France.
Purpose: Radiation exposure for vascular interventionalists is still a concern. The aim of this study was to assess the value of advanced imaging guidance on radiation exposure and iodinated contrast volume during endovascular treatment of lower extremity arterial disease (LEAD).
Materials And Methods: It was a prospective, randomized, monocentric, pilot, single-operator study, conducted from June 2018 to October 2019.
Metallomics
July 2022
School of Biosciences, The University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK.
Pancreatic ductal adenocarcinoma (PDAC) is a disease that remains refractory to existing treatments including the nucleoside analogue gemcitabine. In the current study we demonstrate that an organometallic nucleoside analogue, the ferronucleoside 1-(S,Rp), is cytotoxic in a panel of PDAC cell lines including gemcitabine-resistant MIAPaCa2, with IC50 values comparable to cisplatin. Biochemical studies show that the mechanism of action is inhibition of DNA replication, S-phase cell cycle arrest and stalling of DNA-replication forks, which were directly observed at single molecule resolution by DNA-fibre fluorography.
View Article and Find Full Text PDFPhys Med
November 2021
Ospedale di Trento, Italy.
Purpose: The assessment of low-contrast-details is a part of the quality control (QC) program in digital radiology. It generally consists of evaluating the threshold contrast (Cth) detectability details for different-sized inserts, appropriately located in dedicated QC test tools. This work aims to propose a simplified method, based on a statistical model approach for threshold contrast estimation, suitable for different modalities in digital radiology.
View Article and Find Full Text PDFDiagnostics (Basel)
August 2021
Department of Occupational and Community Health Nursing, School of Health Sciences, University of Occupational and Environmental Health, 1-1 Iseigaoka, Yahatanishi-ku, Kitakyushu, Fukuoka 807-8555, Japan.
A short curtain that improves on the low versatility of existing long curtains was developed as a dedicated radiation protective device for the over-table tube fluorographic imaging units. The effect of this short curtain in preventing cataracts was then examined. First, the physician lens dose reduction rate was obtained at the position of the lens.