Download full-text PDF |
Source |
---|
Oper Neurosurg (Hagerstown)
November 2024
Department of Neurologic Surgery, Mayo Clinic, Rochester, Minnesota, USA.
Background And Objectives: A typical workflow for deep brain stimulation (DBS) surgery consists of head frame placement, followed by stereotactic computed tomography (CT) or MRI before surgical implantation of the hardware. At some institutions, this workflow is prolonged when the imaging scanner is located far away from the operating room, thereby increasing workflow times by the addition of transport times. Recently, the intraoperative O-arm has been shown to provide accurate image fusion with preoperative CT or MR imaging, suggesting the possibility of obtaining an intraoperative localization scan and postoperative confirmation.
View Article and Find Full Text PDFOper Neurosurg (Hagerstown)
November 2024
Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA.
Background And Objectives: Accurate intraoperative assessment of coronal alignment is critical to achieving favorable clinical outcomes in adult spinal deformity surgery. However, surgical positioning creates challenges in predicting standing coronal alignment. Gravity-based plumblines require an upright posture and are not possible intraoperatively.
View Article and Find Full Text PDFCardiol Rev
January 2025
From the Department of Neurological Surgery, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY.
Endosaccular flow disruption has emerged as a transformative approach for treating wide-neck intracranial aneurysms, which are characterized by neck diameters exceeding 4 millimeters or dome-to-neck ratios below 2. This review examines the technical specifications and clinical outcomes of major endosaccular devices, including the Woven EndoBridge (WEB) device, the Artisse embolization device, the Medina embolization device, the neck bridging device for bifurcation aneurysms, the polycarbonate urethane membrane-assisted device, the Galaxy saccular endovascular aneurysm lattice, and the Contour Neurovascular System. Analysis of pivotal trials reveals varying degrees of efficacy and safety across platforms.
View Article and Find Full Text PDFJBJS Case Connect
January 2025
Department of Orthopaedics, PGIMER, Chandigarh, India.
Case: A 30-year-old man presented with left proximal tibia fracture (open Grade 3A) and a transverse lateral malleolus fracture (Weber B) following direct impact injury. Computed tomography revealed a rare posteromedial tubercle fibula fracture at the posterior inferior tibiofibular ligament (PITFL) insertion, with syndesmosis disruption. Initial damage control included an external fixator.
View Article and Find Full Text PDFJBJS Case Connect
January 2025
Department of Surgery, The Aga Khan University, Karachi, Pakistan.
Case: Thirty-five-year-old man presented with 14 cm segmental tibial defect after crush injury (Gustilo Anderson type-IIIA). Tetrafocal bone transport using Ilizarov frame was performed with 3 osteotomies. Two minor complications-skin invagination and failure at proximal docking site-were addressed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!