A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of histamine bronchial challenges with the Wright nebulizer and the dosimeter. | LitMetric

In twenty adult asthmatics studied in a stable state, histamine bronchial challenges were carried out at one-week intervals with the Wright nebulizer and with the dosimeter-DeVilbiss apparatus. Dose-response curves were analysed for sensitivity, defined as the minimal histamine dose causing a 20% fall in FEV1 (PC20), and for reactivity, defined as the slope of the dose-response curve once the reaction starts to occur. A significant relationship (r=0.80) was found for the sensitivity obtained with the two nebulizers. PC20 was indeed reproducible within a two folds concentration of histamine in sixteen of the twenty patients. A significant difference (P less than 0.01) was found in the reactivity to the two different apparatus, reactivity being greater with the Wright nebulizer in twelve out of fifteen patients so tested. Sensitivity and reactivity showed a borderline relationship (r=0.47) with the Wright nebulizer but not with the dosimeter. A significant correlation (P less than 0.05) was found to exist between the initial FEV1 (in % of the predicted value) and the observed sensitivity and reactivity as assessed with the Wright nebulizer, but not as assessed with the dosimeter. We conclude that histamine bronchial challenges with the Wright nebulizer and with the dosimeter yield reproducible results if the threshold of a 20% fall in FEV1 is taken as positive. However, the two methods produce different results in terms of reactivity.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1365-2222.1979.tb00482.xDOI Listing

Publication Analysis

Top Keywords

wright nebulizer
24
histamine bronchial
12
bronchial challenges
12
nebulizer dosimeter
12
challenges wright
8
20% fall
8
fall fev1
8
sensitivity reactivity
8
wright
6
nebulizer
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!