A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Alveolar gas concentrations of fluorocarbons-11 and-12 in man after use of pressurized aerosols. | LitMetric

, , 95-98. In dogs, inhalation of fluorocarbon aerosol propellants sensitizes the heart to arrhythmias provoked by intravenous injection of adrenaline. In this research, the concentrations of fluorocarbons-11 and -12, CClF and CClF, have been measured in alveolar gas in man after using pressurized aerosol inhalers. Fluorocarbons were measured breath by breath using an AEI MS12 mass-spectrometer modified to allow sampling from a respiratory mouthpiece. After a single inhalation from an inhaler by six normal volunteers the mean concentration of fluorocarbon-12 in alveolar gas had reached 5·5 μg/ml, giving a mean apparent volume of distribution of 7·94 litres compared with the mean predicted total lung capacity of 6·61 litres. These results suggest that most of the fluorocarbon expelled from the inhaler entered the alveolar gas. The mean alveolar concentration of F-11 was 2·7 μg/ml and the mean apparent volume of distribution was 12·46 litres. The higher volume of distribution with the less volatile F-11 probably reflects the amount dissolved in lung tissue and pulmonary capillary blood. Similar results were obtained in two patients with obstructive airways disease. One volunteer took an inhalation on every breath up to two minutes and reached an alveolar concentration of F-11 of 29·6 μg/ml and of F-12 of 66·9 μg/ml. The concentration of F-11 required to sensitize the dog heart to arrhythmias was 68 μg/ml. Thus there should be no hazards from the amount entering alveolar gas in normal use after a single inhalation. Inhalation upon every breath over a period raises the alveolar concentration to one approaching that which, in the dog, might be hazardous.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC470410PMC
http://dx.doi.org/10.1136/thx.29.1.95DOI Listing

Publication Analysis

Top Keywords

alveolar gas
20
volume distribution
12
alveolar concentration
12
concentration f-11
12
alveolar
8
concentrations fluorocarbons-11
8
man pressurized
8
heart arrhythmias
8
single inhalation
8
μg/ml apparent
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!