. , , 56-67. . Between April 1969 and March 1973, 213 patients had heart valve replacement with frame-mounted autologous or homologous fascia lata or with heterologous pericardial grafts. There were 111 single aortic, 95 single mitral, and seven tricuspid valve replacements. The incidence of hospital and late mortality was each 10% for the entire series and the main causes were myocardial failure and infective endocarditis. The majority of patients obtained significant symptomatic improvement. In patients with aortic replacement there was a statistically significant reduction in cardiothoracic ratio and in the voltage of the electrocardiogram. Regurgitant murmurs developed in 11·6% of aortic patients and in 51·6% after mitral replacement (in 37·5% the murmur has not increased in intensity while in 14·1% it has gradually progressed). None of these mitral patients requires reoperation. Grafts in the tricuspid position have not shown signs of dysfunction or failure. Graft failure has not occurred in the aortic replacement series. From the mitral position six grafts have been removed due to failure. All six were made of autologous fascia and all showed varying degrees of thickening and retraction of cusps. There were six episodes of peripheral embolization (five transient) and one left atrial thrombosis. All seven patients are alive. Anticoagulants were not used. The results of haemodynamic studies and hydrodynamic experiments are discussed and an explanation for graft dysfunction in the mitral position is presented. The actuarial analysis of this series of patients over a period of up to 54 months post-operatively has shown encouraging results.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC470404 | PMC |
http://dx.doi.org/10.1136/thx.29.1.56 | DOI Listing |
Am J Ther
January 2025
Department of Interventional Cardiology, Queen Elizabeth Hospital, Birmingham, United Kingdom.
J Int Med Res
January 2025
Colombo South Teaching Hospital, Colombo, Sri Lanka.
A 70-year-old man developed intermittent fever with chills, severe anorexia, generalized weakness, and mild exertional difficulty in breathing following posterior chamber intraocular lens replacement surgery for a mature white cataract in the left eye. Laboratory tests revealed persistent negative blood cultures, normocytic and normochromic anemia, neutrophilia, and elevated inflammatory markers despite multiple courses of antibiotics. All other investigations conducted to identify the cause of prolonged fever, including transthoracic echocardiography, were negative.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka 589-8511, Japan.
Background: The initial outcomes of transcatheter aortic valve replacement in patients with left ventricular outflow tract calcification are poor. Furthermore, balloon-expandable transcatheter aortic valve replacement is associated with an increased risk of annular rupture, and self-expandable transcatheter aortic valve replacement is associated with worse post-operative residual paravalvular leakage grades. Therefore, developing an optimal method for transcatheter aortic valve replacement for patients with left ventricular outflow tract calcification is desirable.
View Article and Find Full Text PDFBMC Cardiovasc Disord
January 2025
Graduate School of Public Health, St Luke's International University, Tokyo, Japan.
Background: Recent studies revealed an association between small kidney volume and progression of kidney dysfunction in particular settings such as kidney transplantation and transcatheter aortic valve implantation. We hypothesized that kidney volume was associated with the incidence of kidney-related adverse outcomes such as worsening renal function (WRF) in patients with acute heart failure (AHF).
Methods: This study was a single-center retrospective cohort study.
Eur J Cardiothorac Surg
January 2025
Department of Cardiac Surgery, University Hospital Quironsalud Madrid, Spain.
Objectives: The Ross procedure for aortic regurgitation (AR) and abnormal aortic valve morphologies is associated with an increased risk of autograft dilatation. Autograft support may ameliorate this problem. We analyzed the results for all haemodynamic lesions and the effect of autograft support.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!